2.3. Splicing Tight Buffer or Loose Tube Fiber
2
7
STANDARD RECOMMENDED PROCEDURE 003-895 | ISSUE 1 | OctOber 2011 | PAGE 4 OF 11
Cut to:
1
48 inches (250 micron)
35 inches (900 micron)
Fold fiber over
into cassette
5
and store under
4
flanges.
Cover
8
Repeat Step 5
on the other side of
cassette. Loop
and store all fiber
under flanges.
Close cover.
3
TPA-3933
6
TPA-3934
9
TPA-3935