KitchenAid KESC300BWH6 Installation Instructions - Page 2

Browse online or download pdf Installation Instructions for Oven KitchenAid KESC300BWH6. KitchenAid KESC300BWH6 5 pages. 30" (76.2 cm) electric range with self-cleaning thermal/convection oven
Also for KitchenAid KESC300BWH6: Use And Care Manual (5 pages)

Before you start...
Your safety and the safety of others
are very important.
We have provided many important safety
messages in this manual and on your appliance.
Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards
can kill or hurt you and others.
All safety messages will follow the safety alert
symbol and either the word "DANGER"or
"WARNING". These words mean:
You can be killed or seriously injured if you
don't immediately follow instructions.
You can be killed or seriously injured if you
don't follow instructions.
All safety messages will tell you what the potential
hazard is, tell you how to reducethe chance of
injury, and tell you what can happen if the
instructions are not followed.
Cabinet
opening
dimensions
25" (63.5 cm) countertop
depth
and 24" (61 cm) base cabinet
depth,
36" (91.4 cm) countertop
height
Freestanding
Range
Slide-in
Range
For minimum
['_13"
_33 cm} max.__
_
For minimum
13"(33cm)
max.
I__
clearance
to
I
uppercabinet'depth
_
[//
clearance
to
upper
cabinet
depth
_
_-_
the top
of the
I
30" _7&2
cm_ rnin-
.L.
the
top of the
"_"
cooktop
see
/
_hi'_
_i
.....
i_
/
cooktop
see
50" 1 75.2
cm_ m_n. L..."oto.
__
............
_
_ .ore.
cabinet opening
width
_r
T
_--'_..
_"
18" (45.7 cm)
I"__'_
upper cabinet
/
//
_
_
opening aep
upper cabinet
I
--"_:_
to countertop _
/
_
_
I
"_-"_
tooountertop
__"
"_"-
_
1/2"(1._)1
"_.
_-
I
"_-.
opening
width
"_"_"_
4"
I
"_,
corners
I
41
.
_
'
--
30-3/8"
(77 2 cm)
4" (10.2
cm)
_
,,,i..
_,_._._=
rain. clearance
_
from both sides
from both sides
junction
box -
of range to side
_ junction
box - 8" (20.3 cm) to
of range to side
8" (20.3 cm) to
wall or other
22" (55.9 cm) from either
wall or other
22" (55.9 cm) from
combustible
cabinet,
7" (17.8 cm) max. from
combustible
either
cabinet,
material,
floor.
material.
7" (17.8 cm) max.
I
I
from floor.
I
I
_
I
/"
I
/
_
_-|1/I
7/8"
rain.
required
LI
min. required
""
}
\
between
cutout
and
cabinet
\
and cabinet
""
door or hinge.
\
\
.,,
door or hinge.
",
Read electrical
and carpentry instructions.
Proper installation is your responsibility. A
qualified technician must install this range. Make
sure you have everything necessary for correct
installation. It is the customer's responsibility to
make sure that the countertop has been properly
prepared and that the installation clearances
specified on the model/serial rating plate are
met. The model/serial rating plate is located on
the oven frame behind the drawer.
Check location
where range will be installed.
The range should be located for convenient use
in the kitchen. Recessed installations must
provide complete enclosure of the sides and rear
of range.
ALL OPENINGS IN THE WALL OR FLOOR
WHERE RANGE IS TO BE INSTALLED MUST
BE SEALED.
IMPORTANT: Some cabinet and building
materials are not designed to withstand the heat
produced by the oven for baking and self-
cleaning. Check with your builder or cabinet
supplier to make sure that the materials used
will not discolor, delaminate or sustain other
damage.
It is the customer's responsibility:
To contact a qualified
electrical
installer.
To assure that the electrical
installation
is
adiquate
and in conformance
with National
Electrical
Code, ANSI/NFPA 70 -- latest
edition*,
or CSA Standard
C22.1, Canadian
Electrical
Code, Part 1 -- latest edition**,
and
all local codes and ordinances.
Note: The metal chassis of the range MUST be
grounded in order for the control panel to work. If
the metal chassis of the range is not grounded, NO
keypads will operate. Check with a qualified
electrician if you are in doubt as to whether the
metal chassis of range is grounded.
Mobile home installation
The installation of this range must conform to the
Manufactured Home Construction and Safety
Standards, Title 24 CFR, Part 3280 (formerly the
Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD, Part 280); or when such
standard is not applicable, the Standard for
Manufactured Homes Installations (Manufactured
Home Sites, Communities and Setups), ANSI
A225.1/NFPA 501A, or with local codes*.
In Canada, the installation of this range must
conform with the current standards
CAN/CSA-Z240 i
latest edition**, or with local
codes.
When this range is installed in a mobile home, it
must be secured to the floor during transit. Any
method of securing the range is adequate as long
as it conforms to the standards listed above.
Four-wire power supply cable must be used in a
mobile home installation. The appliance wiring will
need to be revised. See four-wire electrical
connection, Panel B.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
One Batterymarch
Park
Quincy, Massachusetts
02269
** Canadian
Standard
Association
178 Rexdale Boulevard
Rexdale (Toronto), Ontario Mew 1R3
Panel A
important: Observe all governing
codes and
ordinances.
When installing a range under existing cabinets
and the installation does not meet the minimum
cabinet clearances, install a range hood above
the cooktop to avoid burn hazards.
Grounded
electrical
outlet is required. See
"Electrical requirements," Panel B.
Cabinet opening
dimensions
that are shown
must be used. Given dimensions are minimum
clearances.
Do Not pinch the power supply
cord between
the range and the wall.
Do Not seal range to side cabinets.
Slide-in
*_
Note: 24" (81 cm) rain. when bottom
of wood or metal
cabinet
is protected
by not less than 1/4" (0.64 cm)
flame retardant
miUboard
covered
with not less than
No. 28 MSG sheet steel, 0.015" (0.4 ram) stainless
steel,
0.024" (0.6 ram) aluminum
or 0.020" (0.5 ram) copper.
30" (78.2 cm) rain. clearance
between
the top of the
cooking
platform
and the bottom
of an unprotected
wood or metal cabinet.
Anti-tip
bracket:
The floor anti-tip
bracket
MUST be installed. To
install the anti-tip
bracket
shipped
with the range,
see Panel C and the
anti-tip
bracket template.
ranges:
countertop
preparation
The cooktop sides of the slide-in range fit over
the cutout edge of your countertop.
If you have a square finish (flat) countertop
and the opening width is 30-3/8" (77.2 cm), no
countertop preparation is required.
Formed front-edged
countertops:
Must have
molded edge shaved flat 1!4" (0.64 cm) from
each front corner of opening.
Tile countertops
may need trim cut back
1/4" (0.64 cm) from each front corner and/or
rounded edge flattened.
30-3/8"
......
(77.2 cm
ope.nm
.1/4"
width
(0 64 cm)
30-7/8"
_
Formed
or tiled countertop
(78.4 cm)
trimmed
1/4" (0.64 cm)
_./
back at front corners
of
countertop
opening.
Product dimensions
Freestanding
Range
30
'_
(76.2 cm)_
cooktop
width
8-1/4"
(21 cm)
_-- 44-3/8"
'
(112.7 cm)
overall
height
36" (91.4 cm)
cooktop
height with
feet loosened
1-1/2 turns
27-3/4"
(70.5 cm)
depth with
handle
30
u_
_
(76.2 cm)
width
If countertop opening width
is greater than
30-3/8" (77.2 cm), adjust the 1/4" (0.64 cm)
dimension.
Countertop
must be level. Place level on
countertop, first side to side; then front to back. If
countertop is not level, range will not be level.
Oven must be level for satisfactory baking
conditions.
Cooktop
sides of range fit over
edges of countertop
opening.
Slide-in
Range
When installed
in a 24"
(61 cm) base cabinet
with
25" (63.5 cm) countertop
i
front of oven door
protrudes
1-7/8" (4.8 cm)
beyond
24" (61 cm) base
cabinet.
38" (91.4 cm)
cooktop
height with
feet loosened
1-1/2 turns
(2.Scm)
25-3/4"
(65.4 cm)
depth
handle
30
'_
(78.2 cm)
width