Gardena 4100 Silent Operator's Manual - Page 7
Browse online or download pdf Operator's Manual for Water Pump Gardena 4100 Silent. Gardena 4100 Silent 12 pages. Garden pump
1. Clean the pump housing with a damp cloth.
2. Clean the airflow slots with a soft brush (do not use sharp objects).
4.2 To flush the pump:
After pumping chlorinated water, the pump must be flushed.
1. Pump through lukewarm water (max. 35 °C), possibly adding a mild
cleaning agent (e. g. detergent) until the pumped water runs clear.
2. Dispose of the residues in accordance with local waste disposal
regulations.
5. STORAGE
5.1 To put into storage [ Fig. S1 ]:
CAUTION!
Damage to the pump due to frost!
v Store the pump in a frost-free place.
The product must be stored away from children.
1. Unplug the plug of the mains cable from the mains socket.
2. Close any shut-off valves in the suction line.
3. Open any shut-off valves in the pressure line (accessories, water
stop, etc.).
Therefore the pressure line is depressurized.
4. Unscrew the screw fitting
(5)
of the filler neck
screw
(8)
by hand.
Therefore the pump is drained.
5. Tilt the pump in the direction of the drain (approx. 80°) so that the
pump empties completely.
6. Unscrew the suction hose and the pressure hose.
7. Tighten the screw connection
water drain screw
(8)
by hand (do not use pliers).
8. Clean the pump (see 4. MAINTENANCE).
9. Store the pump in a dry, enclosed and frost-free place.
6. TROUBLESHOOTING
DANGER!
Risk of injury!
Risk of injury due to accidental starting.
v Unplug the plug of the mains cable from the mains socket.
6.1 To loosen the impeller [ Fig. T1 ]:
An impeller blocked by dirt can be loosened.
v Turn the shaft of the impeller
(9)
Therefore the blocked impeller is loosened.
6.2 Troubleshooting table:
Problem
Possible Cause
Pump is running,
Leaky or damaged suction line
but the suction action
[Fig. A2].
doesn't take place
Pump sucks in air at a con
nection point [Fig. A2].
No water available in
the cistern, water tank,
water pipe, etc.
Pump was not filled with water
[Fig. A4].
Water escapes during the
suction process via the
pressure hose.
(6)
and the water drain
(5)
(6)
on the filling opening
and the
clockwise with an insulated screw driver.
Remedy
v Check the suction line
for damage and seal so
is airtight.
v Seal the suction side con
nections airtight.
v Make sure that the water
supply is on the suction side.
v Fill the pump
(see 3.1.1 To start the
pump).
1. Fill the pump again.
2. Hold up the pressure hose.
3. Start the pump again
(see 3.1.1 To start the
pump).
Problem
Possible Cause
Pump is running,
Absolutely vacuumresistant connection is achieved by
but the suction action
using GARDENA Suction Hoses (see 8. ACCESSORIES /
doesn't take place
SPARE PARTS).
Screw fitting on the filler neck
is leaking [ Fig. A2 ].
Air cannot escape, since the
delivery line is closed or
remaining water is in the
pressure hose.
Air cannot escape because the
pressure hose is coiled.
Suction time of 5 min. was
not waited for.
Suction filter or backflow
preventer in the suction hose
are clogged.
The end of the suction hose is
not in the water [Fig. A5].
Suction height is too high
[Fig. A5].
In case of any other difficulties concerning the suction action,
use GARDENA Suction Hoses with Backflow Preventer
(see 8. ACCESSORIES / SPARE PARTS). Fill the pump with
water before starting it.
Pump does not start,
Thermal switch has turned
or stops suddenly during
the pump off because of over
operation
heating.
No power supply to the pump.
RCD has triggered
(residual current).
Pump is not switched on.
Pump is running,
The end of the suction hose is
but the delivery
not in the water [Fig. A5].
drops suddenly
Suction filter or backflow
preventer in the suction hose
are clogged.
No water available in the
cistern, water tank, water
pipe, etc.
Suction line is leaking [Fig. A2]. v Eliminate the leak.
Impeller is blocked.
Pressure hose is kinked.
NOTE:
Repairs must only be done by the GARDENA service departments or
specialist dealers approved by GARDENA.
v For any other malfunctions please contact the GARDENA service
department.
7. TECHNICAL DATA
Garden pump
Unit
Rated power
W
Mains voltage
V (AC)
Remedy
v Check the seal (replace
if necessary) and tighten
the screw fitting by hand
(do not use pliers).
v Open any shutoff valves
(e. g. nozzle) in the delivery
line, or drain the pressure
hose.
1. Lay out the pressure hose
straight along its entire
length.
2. Lay the hose from the pump
outlet upwards.
3. Do not kink the pressure
hose at the pump outlet.
4. Open all consumers maxi
mum.
v Wait up to 5 minutes for the
pump to pump water.
v Clean the suction filter or
the back flow preventer.
v Submerge the end of the
suction hose deeper in the
water.
v Reduce the suction height.
v Let the pump cool down,
empty the pump and fill it
again.
v Observe the max. media
Temperature (35 °C).
v Check the fuses and electrical
plug connections.
v Unplug the plug from the
mains socket and contact
the GARDENA Service.
v Push the On / Off switch to the
position On.
v Submerge the end of the
suction hose deeper in the
water.
v Clean the suction filter or the
back flow preventer.
v Make sure that the water
supply is on the suction side.
v Loosen the impeller.
v Lay the pressure hose with
out kinks and do not kink the
pressure hose at the pump
outlet.
Value
Value
Value
(Art. 9050)
(Art. 9054)
(Art. 9056)
550
600
650
220 – 240
220 – 240
230
11