ALIGNER CCD2.0WIFI Installation And Manual - Page 13
Browse online or download pdf Installation And Manual for Test Equipment ALIGNER CCD2.0WIFI. ALIGNER CCD2.0WIFI 16 pages.
The angles that are calibrated are indicated by the following abbreviations, (see Figure 21).
AFL
Alignment Front Left
AFR
Alignment Front Right
ARL
Alignment Rear Left
ARR
Alignment Rear Right
CFL
Camber Front Left
CFR
Camber Front Right
CRL
Camber Rear Left
CRR
Camber Rear Right
TFL
Toe Front Left
TFR
Toe Front Right
TRL
Toe Rear Left
TRR
Toe Rear Right
LFL
Level Front Left
LFR
Level Front Right
LRL
Level Rear Left
LRR
Level Rear Right
The calibration of the detectors is divided into 8 phases, which are described in detail, also graphically, in
the calibration program.
In phases 1 and 2 the front and rear left detectors are mounted and the Alignment and Left Level Gauge
angles are calibrated (AFL, ARL, LFL, LRL).
In phases 3 and 4 the front and rear detectors are mounted and the Right Alignment and Level Gauge
angles are calibrated (AFR, ARR, LFR, LRR).
In phases 5 and 6 the front left and front right detectors are mounted and the front convergence and
inclination angles are calibrated (TFL, TFR, CFL, CFR).
In phases 7 and 8 the rear left and rear right detectors are mounted and the rear convergence and
inclination angles are calibrated (TRL, TRR, CRL, CRR).
Figure 21
R0368
Cod. R0368 ‐ rev.1.0
(03/2020)