ALIGNER CCD2.0WIFI Installation And Manual - Page 13

Browse online or download pdf Installation And Manual for Test Equipment ALIGNER CCD2.0WIFI. ALIGNER CCD2.0WIFI 16 pages.

ALIGNER CCD2.0WIFI Installation And Manual
 The angles that are calibrated are indicated by the following abbreviations, (see Figure 21). 
 
 
 
AFL 
Alignment Front Left
 
AFR 
Alignment Front Right
 
ARL 
Alignment Rear Left 
 
ARR 
Alignment Rear Right
 
CFL 
Camber Front Left 
 
CFR 
Camber Front Right 
 
CRL 
Camber Rear Left 
 
CRR 
Camber Rear Right 
 
TFL 
Toe Front Left 
 
TFR 
Toe Front Right 
 
TRL 
Toe Rear Left 
 
TRR 
Toe Rear Right 
 
LFL 
Level Front Left 
 
LFR 
Level Front Right 
LRL 
Level Rear Left 
 
LRR 
Level Rear Right 
 
 
 
   
 
The calibration of the detectors is divided into 8 phases, which are described in detail, also graphically, in 
the calibration program. 
 
In phases 1 and 2 the front and rear left detectors are mounted and the Alignment and Left Level Gauge 
angles are calibrated (AFL, ARL, LFL, LRL). 
 
In  phases  3  and  4  the  front  and  rear  detectors  are  mounted  and  the  Right  Alignment  and  Level  Gauge 
angles are calibrated (AFR, ARR, LFR, LRR). 
 
In  phases  5  and  6  the  front  left  and  front  right  detectors  are  mounted  and  the  front  convergence  and 
inclination angles are calibrated (TFL, TFR, CFL, CFR). 
 
In  phases  7  and  8  the  rear  left  and  rear  right  detectors  are  mounted  and  the  rear  convergence  and 
inclination angles are calibrated (TRL, TRR, CRL, CRR). 
 
 
 
 
Figure 21 
R0368
 
Cod. R0368 ‐ rev.1.0
(03/2020)