AEG 49669GO-MN User Manual - Page 35
Browse online or download pdf User Manual for Oven AEG 49669GO-MN. AEG 49669GO-MN 38 pages. 90cm
NAtUrAl GAs coNVErsIoN
Model 49669Go-MN
this appliance is supplied set up to for lpG usage . a
conversion kit is included with the product for natural
gas usage . the conversion kit contains 6 injectors and
natural gas sticker .
please follow the procedure below if a conversion to
suit natural gas is required .
1 . remove the hotplate trivets, burner caps and burner
crowns to access the hotplate injectors . replace the
factory fitted injectors with the appropriate injectors,
as supplied . refer to injector orifice table for injector
sizes . the injector size is stamped on the side of
the injector .
2 . turn on the gas supply and at each new connection
check for leaks using soapy water: each hotplate
valve should be turned on, one at a time, and the
injector hole blanked off for several seconds .
3 . One by one, turn the knobs to minimum and adjust
the bypass screw (accessible when the knob is
removed) until a small stable flame results . turn the
knob to maximum and then back to minimum to
ensure that the correct minimum flame
is maintained .
4 . attach the natural gas sticker to the cooker, near
the gas supply inlet . cover the lpG label that is
factory fitted .
flame size adjusted to maximum
flame size adjusted to minimum
Bypass screw
control knob shaft
35