Garmin Boat Switch Installation Instructions Manual - Page 11

Browse online or download pdf Installation Instructions Manual for Marine Equipment Garmin Boat Switch. Garmin Boat Switch 27 pages. Pre-configured digital switching system

Garmin Boat Switch Installation Instructions Manual
Wire Label
CH 27-MOMENTARY 3
(10A)
CH 28-ALWAYS ON(10A)
CH 29-ALWAYS ON(10A)
CH 30-START BATTERY
SENSE (optional)
CH 32 TANK SENSOR
GROUND
X2 Breakout Wire Connections
One grouping of breakout wires on the X2 wiring harness allows you to add a physical switch to a pump or
device connected to a digital switch on the specified primary wires of the X1 and X2 wiring harnesses.
Connecting these wires to the CH 32 TANK SENSOR GROUND wire on the X2 wiring harness through a physical
momentary switch triggers the associated latching, dimming, or momentary switch for devices connected to the
correlated channels on the primary harnesses.
The other grouping of breakout wires on the X2 wiring harness is used when configuring the device. Connecting
these wires to the CH 32 TANK SENSOR GROUND wire on the X2 wiring harness through a physical momentary
switch triggers the associated configuration command.
NOTE: Only momentary switches should be used for physical switches. Using physical latching or toggle
switches can override the Garmin Boat Switch device and disable digital switching on that channel through the
connected Garmin chartplotter.
Wire Label
SWITCH INPUT: ALL FUSE
RESET
SWITCH INPUT: CH12
BILGE 1 (OPTIONAL)
SWITCH INPUT: CH13
BILGE 2 (OPTIONAL)
SWITCH INPUT: CH11
LIVEWELL (OPTIONAL)
SWITCH INPUT: CH27
MOMENTARY 3
(OPTIONAL)
1
All switches on the Garmin Boat Switch device must be configured in the chartplotter software to function properly
Wire
Wire Color
Gauge
Orange with
14 AWG
black stripe
Purple with
14 AWG
black stripe
Green with
14 AWG
black stripe
Yellow with
16 AWG
black stripe
Brown with
16 AWG
black stripe
Wire
Wire Color
Gauge
Black
18 AWG
Brown
18 AWG
Red
18 AWG
Orange
18 AWG
Yellow
18 AWG
Software
Wire Function
Fuse Rating
10A
Provides a momentary switch output
10A
Provides unswitched constant power.
10A
Provides unswitched constant power.
Optional connection that monitors start
battery voltage. This information is
N/A
provided to the NMEA 2000 network
using PGN 127508.
Connects to the ground wire from a tank
sensor or physical bypass switch. This
should be used with sensors connected
to channels 6 and 7 on the X1 wiring
N/A
harness, channels 22 and 23 on the X2
wiring harness, and all of the breakout
wires for physical switches on both
harnesses.
Wire Function
Grounding this wire part of one option for resetting the
software fuses
(Resetting All Software Fuses, page
Momentary switch input for a bilge pump connected to
CH 12-BILGE 1 MANUAL(10A) on the X1 wiring harness.
Momentary switch input for a bilge pump connected to
CH 13-BILGE 2 MANUAL(10A) on the X1 wiring harness.
Momentary switch input for a live-well pump connected
to CH 11-LIVEWELL(10A) on the X1 wiring harness.
Momentary switch input for CH 27-MOMENTARY 3 (10A)
on this wiring harness.
23).
(Switch Configuration, page
18)
1
.
11