Fujitsu BS2000 SE Series Manual - Page 10

Browse online or download pdf Manual for Server Fujitsu BS2000 SE Series. Fujitsu BS2000 SE Series 42 pages. Server unit x86
Also for Fujitsu BS2000 SE Series: Quick Manual (43 pages), Operating Manual (22 pages), Operating Manual (20 pages), Operating Manual (25 pages)

Fujitsu BS2000 SE Series Manual
Powering on the MU via iRMC
Enter localhost into the address bar of the browser (or alternatively the FQDN of the
Ê
powered-on MU) and press enter:
As soon as the login window is displayed, the login to the SE Manager can be performed
(see
"How do I log in on the SE Manager?" on page

2.4 How do I power on a Management Unit via iRMC?

Requirement
The iRMC (integrated Remote Management Controller) of the Management Unit is
accessible.
Procedure
Open a browser window on the administrator PC
Ê
Enter the IP address of the iRMC of the MU
Ê
I
The browser displays the iRMC's graphical user interface with a note in the work area that
it is necessary to log in on the iRMC:
Click Login.
Ê
10
If the browser now displays a warning about the security certificate, click
Continue to this website.
Calling the SE Manager
7).
U41857-J-Z125-2-76