Powering on the MU via iRMC
Enter localhost into the address bar of the browser (or alternatively the FQDN of the
Ê
powered-on MU) and press enter:
As soon as the login window is displayed, the login to the SE Manager can be performed
(see
"How do I log in on the SE Manager?" on page
2.4 How do I power on a Management Unit via iRMC?
Requirement
The iRMC (integrated Remote Management Controller) of the Management Unit is
accessible.
Procedure
Open a browser window on the administrator PC
Ê
Enter the IP address of the iRMC of the MU
Ê
I
The browser displays the iRMC's graphical user interface with a note in the work area that
it is necessary to log in on the iRMC:
Click Login.
Ê
10
If the browser now displays a warning about the security certificate, click
Continue to this website.
Calling the SE Manager
7).
U41857-J-Z125-2-76