Replacement routines
Ê Push the power-distribution module backward until the bolts (A) disengage.
Ê Lift the power-distribution module upward and remove it.
Installing the new power-distribution module
Ê Place the new power-distribution module onto the bolts (A).
Ê Push the power-distribution module toward the front until the bolts (A)
engage.
Ê Fasten the power-distribution module with the two screws (see circles in
figure
15).
Ê Connect the power cables to the HDD backplane and the system board (see
the cabling plans in the Appendix of the Options Guide).
Ê Close the server (for a detailed description see the Options Guide).
Ê Reinstall the power supply unit(s) before you push the server into the rack.
Ê Connect all power plugs (for a detailed description see the Options Guide).