Also for Fujitsu fi-4530C: Installation Procedures Manual (7 pages), Installation Procedures Manual (9 pages), Brochure & Specs (2 pages), Installation Procedures (3 pages), Consumable Replacement And Cleaning Instructions (14 pages), Cleaning Instructions Manual (13 pages), Cleaning Instructions (2 pages), Instruction Manual (10 pages), Installation Procedure (5 pages)

Fujitsu fi-4530C Getting Started
Appendix2
The glass of the inside of the
ARNI N G
ADF becomes hot during opera-
tion.
When you clean the inside of the
scanner, turn off the power and
unplug the AC adapter from the
outlet and wait for at least three
minutes.
Do not turn off the scanner when
you clean the Feed rollers or
Eject rollers.

■ Cleaning Materials

Cleaning
Parts No.
Materials
Cleaner F1
CA99501-
(or isopropyl
0013
alcohol)
Lint-free dry
- Commercially available one
cloth
For details about the cleaning materials, contact the
FUJITSU scanner dealer where you purchased the scan-
ner.

■ Cleaning Method

The ADF must be cleaned with a lint-free cloth moist-
ened with the Cleaner F1.
AP-4
DAILY CARE
Remarks
1 bottle
Moisten a cloth with
this fluid and wipe the
scanner clean.
■ Locations and Cycle for Cleaning
Part to clean
Pad ASSY
Pick roller
Feed rollers
Plastic rollers
Eject rollers
Sheet guides
Glass
Ultra sonic sensor
The scanner must be cleaned more fre-
ATTENTION
quently if you scan any of the following
type of sheets:
Documents of coated paper
Documents that are almost com-
pletely covered with printed text or
graphics
Chemically treated documents such as
carbonless paper
Documents containing a large amount
of calcium carbonate
Handwritten documents
For details on the cleaning the ADF, refer to "3.2 clean-
ing the ADF" in fi-4530C Operator's Guide on the Setup
CD-ROM".
Standard Cleaning Cycle
Clean these parts after every
5,000 scans.