Fujitsu M3096GX Consumable Replacement And Cleaning Instructions - Page 6
Browse online or download pdf Consumable Replacement And Cleaning Instructions for Scanner Fujitsu M3096GX. Fujitsu M3096GX 12 pages. Departmental document scanners
Also for Fujitsu M3096GX: Installation Procedures Manual (7 pages), Installation Procedures Manual (9 pages), Brochure & Specs (2 pages)
M3096EX/GX C
onsuMablE
R
C
EplaCEMEnt and
lEaninG
R
p
eplaCinG the
Misfeeds can be caused by a worn Pick Roller. The life span of the Pick
Rollers is about 200,000 sheets or 1 year if maintained properly. If NCR
or carbonless paper is used the life span may be decreased by half.
•
Lift the ADF Lever and
open the ADF.
•
Remove the two thumb
screws and lift the Pick
Roller Cover out of the
ADF.
•
Compress the ends of
the retaining hook and
remove from the groove
in the shaft.
•
Slide the retaining hook
and Bushing A toward
the sponge roller.
•
Slide the roller shaft
towards the center of
the scanner (direction of
Arrow A) to remove the
roller shaft from the rear
ADF frame.
•
Now slide toward the
back of the scanner
(direction of Arrow B) to
remove the Pick Roller
Shaft from the ADF.
•
Remove the bushings and the retaining hook from the roller shaft.
Retaining Hook
Bushing
i
nstRuCtions
R
iCK
olleR
Thumb
Screw
Bushing
Thumb
Screw
Pick Roller
Cover
Bushing A
Retaining Hook
A
B
Bushing