Also for Fujitsu ETERNUS DX Disk: User Manual (35 pages), User Manual (42 pages), Configuration Manual (28 pages), Configuration Manual (44 pages), Configuration Manual (28 pages), Configuration Manual (25 pages), Configuration Manual (32 pages), Configuration Manual (35 pages), Configuration Manual (31 pages), Configuration Manual (43 pages), Configuration Manual (21 pages), Configuration Manual (24 pages)

Fujitsu ETERNUS DX Disk Configuration Manual
Chapter 6
Required Driver Parameters
6.1
Setting Up the Parameters
The parameters in the "/kernel/drv/fjpfca.conf" configuration file need to be edited as described below.
Original configuration file must be backed up before editing.
Example:
cp /kernel/drv/fjpfca.conf ./ fjpfca.conf.backup
Edit the configuration file according to the following parameter list.
6.1.1
"fjpfca.conf" Parameter Values
These settings are common for all Solaris 10 OS, Solaris 9 OS, and Solaris 8 OS versions.
Comment out any items that are not required by putting a "#" at the beginning of the line.
Setting value (for
Parameter
direct connection)
alias
Set if required
port
Not required
fcp-bind-
Not required
target
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Oracle Solaris
Setting value
Remarks
(for switch connec-
tion)
Set if required
Set an alias name for the WWN.
It is easier to edit the setting files if this alias name is set.
nport
Link speed may be set to a fixed value. (*1)
Set the topology and link speed.
port="<Instance name>:<Topology>:<Link speed>"
The following <topology> parameters may be used:
nport: Switch connection
loop: Direct connection
The following <link speed> parameters may be used:
sp1 for 1Gbit/s links
sp2 for 2Gbit/s links
sp4 for 4Gbit/s links
See remarks
Binds the instance and the ETERNUS DX/AF storage systems' CA
port together.
fcp-bind-target="<Instance name>t<SCSI target ID>:<alias name>"
(<WWN> can be used instead of the <alias name>.)
22
Copyright 2017 FUJITSU LIMITED
P3AM-3712-15ENZ0