Fujitsu Eternus DX90 S2 Configuration Manual - Page 18

Browse online or download pdf Configuration Manual for Storage Fujitsu Eternus DX90 S2. Fujitsu Eternus DX90 S2 28 pages. Server connection. (fibre channel) for aix
Also for Fujitsu Eternus DX90 S2: User Manual (35 pages), User Manual (42 pages), Manual (18 pages), Instal Setup (20 pages), Configuration Manual Server Connection (13 pages), Hardware Installation (23 pages), Configuration Manual (15 pages), Configuration Manual (38 pages)

Fujitsu Eternus DX90 S2 Configuration Manual
Chapter 6
Installing the iSCSI Software Initiator and Setting Up the Server
6.2
Setting Up the Server
3
Confirm the iSCSI Initiator name.
Use the "iscsiutil" command to check the iSCSI Initiator name.
The iSCSI Initiator name shown here is used for the ETERNUS DX settings.
# iscsiutil -l
4
Save the statically-recognized iSCSI target information in the kernel registry.
Use the "iscsiutil" command to save the iSCSI target information.
# iscsiutil [iscsi-device-file] -a -I <ip-address>
Example:
For an ETERNUS DX with a connection target iSCSI port IP address of 192.1.1.120:
# iscsiutil -a -I 192.1.1.120
5
Confirm the iSCSI target information is now in the kernel registry.
# iscsiutil -p -D
6
Set whether CHAP authentication is to be used or not.
If CHAP authentication is to be performed, set "CHAP". If CHAP authentication is not required, set
"None".
Example:
When CHAP authentication is not used:
# iscsiutil -t authmethod None
Note:
# iscsiutil -t authmethod CHAP None
The above command sets CHAP authentication to operate according to the ETERNUS DX setting. The
CHAP authentication method is selected if the ETERNUS DX uses CHAP for its responses, otherwise CHAP
authentication is not performed.
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (iSCSI) for HP-UX
[-P <tcp-port>][-M <portal-grp-tag>]
18
Copyright 2014 FUJITSU LIMITED
P3AM-3402-14ENZ0