Dell Force10 S2410 Manual - Page 17
Browse online or download pdf Manual for Server Dell Force10 S2410. Dell Force10 S2410 42 pages. Installing the s2410 system
Also for Dell Force10 S2410: Quick Start Manual (31 pages)
Figure 4-2. S2410 Two-post (Front-mounted) Rack-mounting
Four-Post Rack-mounting with Threaded Rails
Ensure that there is adequate clearance surrounding the cabinet or rack to permit access and airflow. If
you are installing two S2410 systems side-by-side, position the two S2410 chassis at least 5 inches (12.7
cm) apart to permit proper airflow.
Attach the rack ears first, using only the supplied screws (see
then follow the steps below to install the S2410 chassis into a four-post 19-inch equipment rack, using the
attached front mounting brackets and the optional adjustable rear-mounting brackets.
Step
Task
Align the three screw holes of the adjustable rear mounting bracket with the three holes in the S2410 chassis, and
1
secure the mounting bracket with three screws.
Figure 4-3. Four-post Rack-mounting with Adjustable Rear-mounting Brackets, Step 1
Attaching the Rack Ears on page
15), and
Installing the S2410
|
17