Dell PowerEdge 2970 Information Update - Page 3

Browse online or download pdf Information Update for Server Dell PowerEdge 2970. Dell PowerEdge 2970 29 pages. System memory information update — 8 gb memory modules
Also for Dell PowerEdge 2970: Update Manual (14 pages), Installation Manual (10 pages), Information Update (7 pages)

Dell PowerEdge 2970 Information Update

System Board Jumpers

The jumper settings shown in Figure 6-1 and described in Table 6-1 of your system's Hardware Owner's
Manual are incorrect.The correct settings are shown in Figure 1 and described in Table 2.
Figure 1. System Board Jumpers
Table 2. System Board Jumper Settings
Jumper
Setting
NVRAM_CLR
PWRD_EN
Description
(default)
The configuration settings are retained at system boot.
The configuration settings are cleared at the next system boot. (If the
configuration settings become corrupted to the point where the system
will not boot, install the jumper and boot the system. Remove the jumper
before restoring the configuration information.)
(default)
The password feature is enabled.
The password feature is disabled.