19. At the default installation screen, click Next to begin the installation.
20. At the Congratulations screen, click Reboot.
21. After the system reboots, log in as root.
22. Disable SELinux by editing the file /etc/selinux/config, and change the line SELINUX=enforcing to
SELINUX=disabled. These changes take effect after rebooting.
23. Disable these unused services by running the following command-line script:
CHK_OFFs="auditd autofs cups ip6tables iptables nfslock netfs portreserve postfix\
qpidd rhnsd rhsmcertd rpcgssd rpcidmapd rpcbind"
for i in ${CHK_OFFs}; do
chkconfig $i off
service $i stop
done
Dell PowerEdge C5220: Hadoop MapReduce Performance
A Principled Technologies test report 12