FTOS(conf)#interface range tengigabitethernet 0/0 – 47
Note: The message below will be displayed if there are FC ports.
% Warning: Non-existing ports (non configured) are ingnored by interface-range
FTOS(conf-if-range-te-0/0-47)#switchport
FTOS(conf-if-range-te-0/0-47)#no shutdown
2.8
Enable Jumbo Frames
FTOS(conf-if-range-te-0/0-47)#mtu 12000
2.9
Enable flow control
FTOS(conf-if-range-te-0/0-47)#flowcontrol rx on tx off
2.10
Configure spanning tree on edge ports
FTOS(conf-if-range-te-0/0-47)#spanning-tree rstp edge-port
FTOS(conf-if-range-te-0/0-47)#exit
2.11
Configure port channel for LAG
These commands create a port channel or LAG.
FTOS(conf)#interface Port-channel 1
FTOS(conf-if-po-1)#mtu 12000
FTOS(conf-if-po-1)#switchport
FTOS(conf-if-po-1)#no shutdown
FTOS(conf-if-po-1)#exit
2.12
Configure QSFP ports for LAG
This step assigns the 40Gb QSFP ports to the Port Channel.
FTOS(conf)#interface range fortyGigE 0/48 , fortyGigE 0/52
FTOS(conf-if-range-fo-0/48,fo-0/52)#mtu 12000
FTOS(conf-if-range-fo-0/48,fo-0/52)#no shutdown
9
SCG1007
Dell Networking S5000 Switch Configuration Guide for EqualLogic SANs