Switch configuration (OS 9.x)
2.4

Optional stack configuration

Note: If choosing to use a stack configuration instead of LAG, follow the instructions in this section instead of
those in section 2.1.
One advantage of stacked switches is that they can be managed as a single switch. However, firmware
updates will update all members of the stack simultaneously and therefore should only be done during
planned downtime.
2.4.1

Delete startup configuration on first switch

Dell>enable
Dell#delete startup-config
Proceed to delete startup-config [confirm yes/no]yes
Dell#reload
System configuration has been modified. Save? [yes/no]no
Proceed with reload [confirm yes/no]yes
Note: The switch will reboot.
2.4.2

Configure stack on the first switch

Dell>enable
Note: After the startup configuration is deleted, the factory default enable mode password is calvin.
Dell#configure
Dell(conf)#stack-unit 1 priority 1
Dell(conf)#stack-unit 1 stack-group 12
Dell(conf)#stack-unit 1 stack-group 13
Dell(conf)#exit
Dell#copy running-config startup-config
Dell#reload
2.4.3

Delete startup configuration on the second switch

Dell>enable
Dell#delete startup-config
Proceed to delete startup-config [confirm yes/no]yes
Dell#reload
System configuration has been modified. Save? [yes/no]no
Proceed with reload [confirm yes/no]yes
Note: The switch will reboot.
15