Dell S4048-ON Configuration Manual - Page 28

Browse online or download pdf Configuration Manual for Switch Dell S4048-ON. Dell S4048-ON 30 pages. Enterprise switches
Also for Dell S4048-ON: Configuration Manual (19 pages), Troubleshooting Manual (29 pages)

Dell S4048-ON Configuration Manual
Switch configuration (OS 10.x)
3.3.4
Remove DCB policies and apply standard flow control on port-channel
member ports
OS10(config)# interface range ethernet 1/1/49,1/1/50
OS10(conf-range-eth1/1/49,1/1/50)# no priority-flow-control
OS10(conf-range-eth1/1/49,1/1/50)# no ets
OS10(conf-range-eth1/1/49,1/1/50)# no qos-map traffic-class
OS10(conf-range-eth1/1/49,1/1/50)# no service-policy output type queuing
<queuing-policy-name>
OS10(conf-range-eth1/1/49,1/1/50)# no service-policy input type network-qos
<policy-map-name>
OS10(conf-range-eth1/1/49,1/1/50)# flowcontrol receive on
OS10(conf-range-eth1/1/49,1/1/50)# flowcontrol transmit off
OS10(conf-range-eth1/1/49,1/1/50)# exit
OS10(config)#
OS10(config)# interface port-channel 1
OS10(conf-if-po-1)# no switchport trunk allowed vlan <vlan-id>
OS10(conf-if-po-1)# switchport access vlan 1
OS10(conf-if-po-1)# exit
OS10(config)#
3.3.5

Revert to default VLAN ID on switch and arrays

Once DCB is disabled on the switch, the PS Series arrays will no longer use the VLAN ID that was configured
when DCB was enabled. The arrays will revert to the default or native VLAN. Therefore, a valid VLAN must
be configured for all host servers, switches, and PS Series array members. A valid VLAN can use the default
or native VLAN ID (typically 0 or 1) or a specific VLAN can be configured (for example, VLAN 100). If a non-
default VLAN is configured, then any ports connected to the arrays must be configured as untagged.
The previous steps in section 3.3.3 and 3.3.4, revert the switch ports to default native vlan 1. Use the
following command to remove VLANs other than vlan 1 from the switch configuration.
OS10(config)# no interface vlan <vlan-id>
28
Dell EMC Networking S4048-ON Switch Configuration Guide for Dell PS Series SANs | SCG1026