EarthStone pagw 110 Installation, Operation And Maintenance Instructions - Page 15

Browse online or download pdf Installation, Operation And Maintenance Instructions for Oven EarthStone pagw 110. EarthStone pagw 110 17 pages. Gas fired oven
Also for EarthStone pagw 110: Dimensional Drawing (2 pages), Installation, Operation And Maintenance Instructions (18 pages)

EARTHSTONE OVENS PRE-ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS
Improper Installation (cont)
2) Oven is not closed to plenum/attic and is open to HVAC airflow.
Air flow
3) Altered air flow from air intake in a separate room with low pressure.
Low pressure is created
by HVAC or any air moving
equipment outside oven
room
In this case the air intake located on the rear of the oven should be closed.
Roof
Air flow
Ceiling
Air flow
Air flow
Air Intake
Installing a sealed enclosure around the oven
shell may cause improper operation by
starving the burner system of combustion air.
The air flow which travels above will cause
"negative pressure" below where the gas
burner is located. The air underneath will travel
towards the air flow above creating a suction
which will force the gas flame downwards. To
prevent this a non-combustable lid must be
placed above the oven.
Roof
Air flow
Ceiling
Air flow to oven is altered as air
moves from normal to low
Air Intake
pressure
Air flow
15