Installation
Adjusting depth
^ The depth of the unit ("T" in the
diagram) can be adjusted from
13
3
10
/
" to 14
16
means of the adjustable brackets..
^ Slightly loosen the screws holding the
brackets.
^ Pull the brackets out to the desired
depth "T".
^ Tighten the screws again.
^ To align the depth on the underside
of the hood, loosen the screws on the
angle plate and move it to the
position required.
^ If the range of adjustment is
insufficient, unscrew the bracket
completely, rotate it, and use the
longer side.
^ Tighten the screws again.
/
" (275 to 360 mm) by
16
To install a plywood backing
The whole weight of the installed
ventilation system has to be
supported by the mounting plates.
They must be firmly attached to stud
framing behind the drywall. If studs
are not available directly behind
both mounting plates, a plywood
backing (min. 2" (51 mm) thick)
spanning at least two studs must be
installed. Failure to adequately
support the weight as stated may
result in the ventilation system falling
off the wall, causing personal injury
and property damage.
(If plywood backing is not needed,
proceed to "Wall attachment".)
^ Determine and mark the top edge of
the appliance. It must be at least
3
S + 17
/
" (S + 450 mm) in order to
4
comply with the safety height (see
"Appliance Dimensions").