Miele DA 2270 EXT Operating And Installation Instructions - Page 28
Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DA 2270 EXT. Miele DA 2270 EXT 40 pages. Cooker
Also for Miele DA 2270 EXT: Operating And Installation Manual (40 pages), User Manual (40 pages)
Installation
Fitting the non-return flap
(not needed for recirculation mode)
^ If a non-return flap is not present in
the venting system, the non-return
flap supplied must be fitted onto the
exhaust socket in the motor unit. The
flaps must open upwards.
DA 2250, DA 2270: 1 non-return flap
DA 2210: 2 non-return flaps
Building in
The rangehood is designed for
installation in wall units, rangehood
housing units, and above breakfast
bars or island areas.
Check prior to installation that the top of
the appliance will be accessible after
installation.
If this is not the case, install the exhaust
ducting and prepare the electrical
connection before installation.
28
^ Place the appliance in the cut-out
from below and align it.
^ Secure the rangehood by the frame
using 3.5 x 16 mm screws.
^ Before using the appliance for the
first time, take the grease filters out
and remove the protective foil from
the filter frame. Then replace the
grease filters.