Also for Miele DA 409: Operating And Installation Instructions (36 pages), Installation Instructions (1 pages), Product Dimensions (2 pages), Operating And Installation Manual (40 pages), Operating And Installation Instructions (36 pages), Operating And Installation Instructions (36 pages), Operating And Installation Instructions (36 pages)

Miele DA 409 Operating And Installation Instructions
Air extraction
If the exhaust is ducted into an inactive
flue, the air must be expelled parallel to
the flow direction of the flue,
_iii
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii
_iiiiiiiii_ii_iiiiiiiiiiii_
Never connect an exhaust hood to
an active chimney, dryer vent, vent
flue, or room venting ductwork.
Seek professional advice before
connecting
an exhaust hood vent to
an existing, inactive chimney or vent
flue.
important!
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature
variations exist, it may
need to be insulated to reduce
condensation,
In some cases, a condensate trap may
also be required to collect and
evaporate any condensation
which may
occur. This optional accessory
is
available for ducts 5" (125 ram) and
7/ " (!50
ram) in diameter.
5
/8
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet. The arrow on the casing
shows the venting direction,
34