Miele DAW 1620 Active Operating And Installation Instructions - Page 25

Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DAW 1620 Active. Miele DAW 1620 Active 36 pages.

Miele DAW 1620 Active Operating And Installation Instructions
a Extraction
b Recirculation
c Ventilation grille positioned at the top for recirculation
de (Only d is required for recirculation mode cooker hoods). The shaded area
represents the wall or ceiling area for the ducting cut-out and for the connec-
tion socket. Recirculation cooker hoods only need a connection socket to be
fitted.
Connection for air extraction  150 mm

Installation distance between hob and cooker hood (S)

Risk of heat damage.
The rising heat generated by a gas hob may damage the cooker hood.
Fitting this cooker hood over a gas hob is not permitted.
When planning the installation distance between the cooking appliance and the
bottom of the cooker hood, the information provided by the cooking appliance
manufacturer must be taken into account.
Unless a greater distance is specified by the cooking appliance manufacturer,
the minimum safety distances indicated below must be ensured.
Please also observe the information given under "Warning and safety instruc-
tions".
Cooking appliance
Electric hob
Electric grill, electric fryer
Gas hob
Installation
Minimum distance S
450 mm
650 mm
Not possible
25