a Extraction
b Recirculation
c Ventilation grille positioned at the top for recirculation
de (Only d is required for recirculation mode cooker hoods). The shaded area
represents the wall or ceiling area for the ducting cut-out and for the connec-
tion socket. Recirculation cooker hoods only need a connection socket to be
fitted.
Connection for air extraction 150 mm
Installation distance between hob and cooker hood (S)
Risk of heat damage.
The rising heat generated by a gas hob may damage the cooker hood.
Fitting this cooker hood over a gas hob is not permitted.
When planning the installation distance between the cooking appliance and the
bottom of the cooker hood, the information provided by the cooking appliance
manufacturer must be taken into account.
Unless a greater distance is specified by the cooking appliance manufacturer,
the minimum safety distances indicated below must be ensured.
Please also observe the information given under "Warning and safety instruc-
tions".
Cooking appliance
Electric hob
Electric grill, electric fryer
Gas hob
Installation
Minimum distance S
450 mm
650 mm
Not possible
25