Main venting duct
We recommend that when several dry-
ers are being installed each dryer
should be fitted with one non-return flap
installed directly on the main venting
duct (R, upper picture). Extra Miele
equipment is required for this purpose.
When up to five dryers are being in-
stalled, the pipe diameter D must be in-
creased according to Table III.
Table III
Number of Dryers
2
3
4 - 5
Magnification factor for
the pipe diameter from
Table II
1
1.25
1.5
Installation - venting
1 Connection to the main venting duct
2 Miele non-return flap
3 Additional Miele adapter
4 Miele vent hose, very flexible
^ Push the non-return flap (2) com-
pletely into the adapter (3).
35