en - Securing a side-by-side combination
. . . with partition wall
The wall a between the side-by-side
appliances must be at least
5/8" (16 mm) thick.
If the door hinges of the refigeration
appliances are next to each other,
you must take into account the thick-
ness of the cabinet fronts and door
handles so that the appliance doors
do not collide and become damaged
if they are opened at the same time.
4
a
If the partition wall a is narrower than
6 5/16" (160 mm), you will need the
side panel heater  from the side-by-
side merging kit to prevent condensa-
tion from forming and any resulting
damage (see section "Installing the side
panel heater").
The side panel heater  is attached to
the right side of the appliance that is on
the left (when seen from the front).
When planning niches, please note
that the niche into which the appli-
ance with the side panel heater  is
installed must be
1/8"-1/4" (3–5 mm) wider.
Connecting the side panel heater
leads to higher energy consumption.