3-1.
Serial Number And Rating Label Location
The serial number and rating information is located on the left side of the unit. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on back cover of this manual.
3-2.
Specifications*
Coolant
Model
Tank
Capacity
Hydracool
1
8 L
*IEC Cooling Capacity States That The Water Inlet Temperature Can Not Exceed 40°C Above Ambient Temperature At A 1L/Min Flow Rate.
**Plug Is Customer Supplied.
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns.
Use With Guns/Torches Rated Up To 600 Amperes.
3-3.
Coolant Specifications
Do not use conductive coolant.
Application
GTAW Or Where High Frequency Current Is Used
GMAW Or Where High Frequency Current Is Not Used
Where Coolant Contacts Aluminum Parts
*Coolants 043810 and 043809 protect to -38°C (-37°F) and resist al-
gae growth.
NOTICE – Use of any coolant other than those listed in the table
voids the warranty on any parts that come in contact with the coolant
(pump, radiator, etc.)
3-4.
Environmental Specifications
A. IP Rating
This equipment is designed for indoor use and is not intended to be used or stored outside.
B. Information On Electromagnetic Compatibility (EMC)
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public
low-voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations,
due to conducted as well as radiated disturbances.
This equipment complies with IEC 61000-3-11 and IEC 61000-3-12.
C. Temperature Specifications
Operating Temperature Range
-10 to 40°C (14 to 104°F)
�
The correction factor on the cooling power at an ambient temperature of 40°C (104°F) is 0.625.
SECTION 3 – SPECIFICATIONS
Maximum Cooling
Input Power
Capacity
1670 Watts
Single Phase
(5698 BTU/hr)
115 VAC
1.0 L/min
50/60 Hz
(1.1 qt/min)
2.5 Amperes
Input Power
Cord with
Plug
2 m
Coolant 050024004
Low Conductivity Coolant 043810*
Distilled Or Deionized Water Okay Above 0°C (32°F)
Coolant 050024004
Low Conductivity Coolant 043810*
Aluminum Protecting Coolant 043809*
Distilled Or Deionized Water Okay Above 0°C (32°F)
Aluminum Protecting Coolant 043809*
IP Rating
IP21
Storage/Transportation Temperature Range
20 to 25°C (68 to 77°F)
Dimensions
Weight
Length: 305 mm
Height: 674 mm
20.7 kg
Width: 263 mm
Coolant