6-6.
Sequence Of Piercing Operation
1
3
90
5
OM-253555 Page 26
�
Complete Parts List is available at www.MillerWelds.com
2
45
4
The pilot arc starts immediately
when trigger is pressed.
Step 1. Connect work clamp to a clean,
paint-free location on workpiece, as close to
cutting area as possible.
Step 2. Hold torch at approximately 45° to
the workpiece. Raise trigger lock and press
trigger. Pilot arc starts.
Step 3. Rotate torch to upright position ap-
proximately 90° to surface. When arc has
pierced through workpiece, start cutting.
Step 4. Maintain approximately 90° torch po-
sition to surface, and continue cutting.
Step 5. Release trigger. Postflow continues
for approximately 20 seconds after releasing
trigger; arc can be instantly restarted during
postflow by raising trigger lock and pressing
90
trigger.
Ref. 254087-A