Miller XT30i Owner's Manual - Page 26

Browse online or download pdf Owner's Manual for Welding System Miller XT30i. Miller XT30i 44 pages.

Miller XT30i Owner's Manual

6-3. Trigger Safety Lock

Trigger Locked

6-4. Plasma Cutting System Practices

Always connect work clamp to a clean,
paint-free location on workpiece, as close to
cutting area as possible.
90
Maintain approximately a 90
workpiece surface for proper cutting results.
1.6 mm
(1/16 in.)
When doing extended (non-shielded)
cutting, maintain approximately 1.6 mm
standoff between electrode and surface.
OM-256 118 Page 22
.
A complete Parts List is available at www.MillerWelds.com
Sparks should pass through the workpiece
angle to the
and out the bottom when cutting.
DO NOT put pressure on shield when
drag cutting; instead, slide shield along
the surface for proper cutting results.
1
Trigger Unlocked
DO NOT start pilot arc without cutting or
gouging as this shortens the service life
of the nozzle and electrode.
Wt
1
Trigger
!
The pilot arc starts immediately
when trigger is pressed.
If sparks flare back from surface, this
usually is an indication that either travel
speed is too fast or amperage is set too low.
Pulling rather than pushing the torch
makes cutting easier. Use a proper guide
or template for accurate cutting operations.
Ref. 253554-A
Ref. 254 087-A