HP ProCurve 1600M Installation Manual - Page 37

Browse online or download pdf Installation Manual for Switch HP ProCurve 1600M. HP ProCurve 1600M 46 pages. Redundant power supply
Also for HP ProCurve 1600M: Specification Sheet (12 pages), Read Me First (8 pages), Reviewer's Manual (27 pages), Supplementary Manual (2 pages), Supplementary Manual (2 pages), Installation Manual (28 pages), Installation Manual (36 pages), Installation Manual (28 pages), Quick Setup Manual (2 pages), Quick Setup Manual (4 pages), User Manual (8 pages), Manual Supplement (28 pages), Read Me First (16 pages), Installation And Removal (2 pages), Installation Manual (12 pages), Planning And Implementation Manual (40 pages), Product End-Of-Life Disassembly Instructions (2 pages), Diagnostics Manual (2 pages), Disassembly Instructions (2 pages)

HP ProCurve 1600M Installation Manual

Environmental

Temperature, From -60 to +4000 m (-197 to +13,123 ft.):
+5 to +40 °C continuous operation
-5 to +55 °C NEBS short-term operation
-40 to +70 °C storage and transportation
Relative Humidity, non-condensing:
5 to 85% R.H. at 40 °C continuous operation
90% R.H. at 28 °C short-term operation
95% R.H. at 40 °C storage and transportation
Earthquake:
NEBS Risk Zone 4
Heat Dissipation (according to GR-63-CORE)
Maximum heat release (based on 125 W operation)
305 mm (12 in.) rack
457 mm (18 in.) rack
Forced-air cooling

Safety

NEBS GR-1089-CORE
UL 1950
CSA 950
EN60950 / IEC 950
Appendix A
2
1080 W/m
per meter of vertical rack space
2
(31 W/ft
per foot of vertical rack space)
2
702 W/m
per meter of vertical rack space
2
(20 W/ft
per foot of vertical rack space)
Specifications
Specifications
37