HP StorageWorks 8/40 - SAN Switch Release Note - Page 27
Browse online or download pdf Release Note for Switch HP StorageWorks 8/40 - SAN Switch. HP StorageWorks 8/40 - SAN Switch 29 pages. Hp storageworks fabric os 6.1.2b release notes (5697-0351, march 2010)
Also for HP StorageWorks 8/40 - SAN Switch: Release Note (30 pages), Release Note (43 pages), Release Note (32 pages)
Port RSCNs are sent to DPC (VIs and VTs) whenever the configuration
changes, which is unrelated to VI/VT. This affects any application that
uses frame redirect zoning.
With both RD and TI zones configured, a connectivity issue can occur
after hafailover and hareboot.
Frame drop was observed on 4-Gb and 8-Gb switches due to a time
window when a port in a trunk goes offline and the route is not properly
recalculated.
An incorrect status (marginal) occurred when the power cord was un-
plugged.
Unexpected errors encountered during Tape Cancel and Selective
Reset processing during tape creation/restore with FICON tape.
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
Workaround: Run cfgdisable and
cfgenable commands.
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
HP StorageWorks Fabric OS 6.1.1b release notes
27