HP StorageWorks 8/40 - SAN Switch Release Release
Port RSCNs are sent to DPC (VIs and VTs) whenever the configuration
changes, which is unrelated to VI/VT. This affects any application that
uses frame redirect zoning.
With both RD and TI zones configured, a connectivity issue can occur
after hafailover and hareboot.
Frame drop was observed on 4-Gb and 8-Gb switches due to a time
window when a port in a trunk goes offline and the route is not properly
recalculated.
An incorrect status (marginal) occurred when the power cord was un-
plugged.
Unexpected errors encountered during Tape Cancel and Selective
Reset processing during tape creation/restore with FICON tape.
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
Workaround: Run cfgdisable and
cfgenable commands.
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
Fixed in Fabric OS 6.1.1b
HP StorageWorks Fabric OS 6.1.1b release notes