HP StorageWorks 8B - FC Entry Switch User Manual - Page 16

Browse online or download pdf User Manual for Switch HP StorageWorks 8B - FC Entry Switch. HP StorageWorks 8B - FC Entry Switch 30 pages. Fabric os release notes version 3.0.1b
Also for HP StorageWorks 8B - FC Entry Switch: Update Manual (9 pages), Installation Instructions Manual (20 pages), User Manual (22 pages), Firmware Release Notes (14 pages), Installation Manual (14 pages), Release Note (26 pages), Manual (50 pages), User Manual (44 pages), User Manual (44 pages), User Manual (38 pages), User Manual (38 pages), User Manual (37 pages), Release Note (16 pages)

HP StorageWorks 8B - FC Entry Switch User Manual
3
Using ISL Trunking
ISL Trunking Telnet Commands
The following table shows the telnet commands used to manage the ISL Trunking feature.
Table 3-1
Telnet Command
portCfgTrunkport
switchCfgTrunk
trunkDebug
trunkshow
For detailed information on how to use these commands, refer to the Fabric OS Reference Guide.
3-2
ISL Trunking Telnet Commands
Description
Use this command to
configure a port to be
enabled or disabled for
ISL Trunking.
Use this command to
enable or disable
trunking on all ports of a
switch.
Use this command to
debug a trunk link
failure.
Use this command to
display ISL Trunking
membership
information.
Example
To enable port 5 for ISL Trunking,
enter:
portCfgTrunkport 5, 1
To disable port 5 for ISL Trunking,
enter:
portCfgTrunkport 5, 0
To enable ISL Trunking on all ports of
a switch, enter:
switchCfgTrunk 1
To disable ISL Trunking on all ports
of a switch, enter:
switchCfgTrunk 0
To debug ports 1 and 2, enter:
trunkDebug 1, 2
To display ISL Trunking membership
information about users, enter:
trunkshow
ISL Trunking User's Guide