HP Xw460c - ProLiant - Blade Workstation Overview - Page 25

Browse online or download pdf Overview for Switch HP Xw460c - ProLiant - Blade Workstation. HP Xw460c - ProLiant - Blade Workstation 35 pages. Mezzanine card installation instructions for supported hp proliant c-class bladesystem servers
Also for HP Xw460c - ProLiant - Blade Workstation: Implementation Manual (35 pages), Error Prevention Manual (12 pages), Technical White Paper (12 pages), Firmware Update (9 pages), Installation Manual (2 pages), Frequently Asked Questions Manual (14 pages), Setup Poster (9 pages), Installation Manual (33 pages), Management Manual (28 pages), Hardware Manual (23 pages), User Manual (33 pages), Optimization Manual (13 pages), Limited Warranty (10 pages), Installation Instructions Manual (10 pages), Installation Instructions Manual (8 pages), Installation Instructions (4 pages), Installation Instructions (2 pages)

HP Xw460c - ProLiant - Blade Workstation Overview
Figure 18. Processor heat sink using fully ducted design (left) versus traditional heat sink in a 1U rack-mount
server (right)
Instant thermal monitoring provides a real-time view of heat, power, and cooling data. The
BladeSystem Onboard Administrator retrieves thermal information from all server blades, storage
blades, and interconnect modules in the enclosure to ensure an optimal balance between cooling,
acoustic levels, and power consumption. The Thermal Logic technology in the BladeSystem Onboard
Administrator keeps fan and system power at the lowest level possible. However, if the thermal load
within the enclosure increases, the Thermal Logic feature instructs the fan controllers to increase fan
speeds to accommodate the additional demand. If high temperature levels occur, the ProLiant
Onboard Administrator (iLO 2) and BladeSystem Onboard Administrator modules provide alerts to
various management tools such as HP Insight Control Environment and HP Systems Insight Manager.
In addition, built-in failsafe procedures shut down devices in the enclosure if temperature levels
exceed specified parameters. This prevents permanent damage to any devices within the enclosure.
HP Thermal Logic includes sophisticated algorithms in each BladeSystem ROM, ProLiant Onboard
Administrator (iLO 2), and BladeSystem Onboard Administrator. In combination, these algorithms
minimize the power and cooling required to maintain the proper HP BladeSystem environment.

Power supplies and enclosure power subsystem

Expecting that power supply technology will advance during the lifecycle of the c7000 enclosure, HP
designed the c7000 power subsystem to be flexible and upgradeable. Customers can choose from
four types of HP BladeSystem c7000 Enclosures to select the one that will work best with their data
center power infrastructure:
Single-phase enclosure that accepts IEC C19-C20 power cords (available worldwide for use with
in-rack power distribution units)
Three-phase enclosure with a pair of US/Japan power cords with NEMA L15-30P power
connectors
Three-phase enclosure with a pair of international power cords with IEC 309, 5-Pin, 16A power
connectors
–48V DC Input Modules using a screw down terminal lug (45DG 4AWG 1/4 2H)
Top view
Side view
25