Aquatel S207E Instruction Manual - Page 4
Browse online or download pdf Instruction Manual for Measuring Instruments Aquatel S207E. Aquatel S207E 8 pages. Wireless level indicator
Install Tank Unit
1
Choose location for Tank Unit on the top of the tank or cistern.
!
Ideal. Unit in centre
of tank
Note - For tanks less than 1500 mm (5') deep mount unit in centre of tank.
- Mount unit at least 100 mm (4") from the high water level.
2
2. Drill a 50mm (2") hole in
tank. For thick concrete tanks
make a 75mm (3") hole.
3
Measure the depth of
tank to the base (or to the
water outlet). Write this
measurement down.
4
Insert Tank Unit in hole and
rotate so tank antenna is on
the lower side (to prevent
water entering unit). Ensure
that the transducer cone
underneath is pointing
directly at the surface of the
water.
For plastic tanks use the supplied screws to attach the Tank Unit to the tank.
For metal tanks first drill 3mm or ¼" holes, and then fasten using the screws.
For concrete tanks drill 6mm or ¼" holes, insert the supplied plastic plugs and then
fasten using the screws.
"
Incorrect. Mount unit
away from ribbed
walls to prevent signal
reflection off walls
"
!
8
!
Correct. For buried tanks
mount unit in centre of lid,
or on bracket mounted in
riser
"
Antenna should be
mounted on the
opposite side
"
Transducer is not
pointing at the surface
"
of the water
!
Water will not enter
!
antenna hole
Transducer is parallel
!
to water