Axis 290A Installation Instructions Manual - Page 8

Browse online or download pdf Installation Instructions Manual for Camera Accessories Axis 290A. Axis 290A 8 pages. Outdoor housing
Also for Axis 290A: Installation Manual (4 pages)

8

Maintenance

Annual maintenance is required to inspect all visible seals for wear and damage. Worn or
damaged seals should be replaced.
Recommendation:
from drying out and to aid opening and closing of the housing. Use an all-purpose silicone
spray for use on electrical equipment and components, and also compatible with rubber,
metal and plastic materials.
Clean the housing with a damp cloth only (not on the window). Do not use chemicals to
clean the housing as this may affect the powder coat finish. The window should only be
cleaned with a dry cloth.
Burnt fuses in the fused terminal block can be replaced to reinstate the power supply of the
camera. Use a 5A, 250 VAC fuse and ensure that the mains is disconnected before
beginning.

Specifications

• Weatherproof to IP66
• CE
• Power requirement: 100-240V AC 60/50Hz
• Operating temperature: -20°C to +42°C (-4F to 108F).
• Approximate weight: 3.2 kg (7.1 lbs)
• Color: RAL 9002 grey white
• Specifications may change without prior notice.
Warning: The housing should not be installed in areas that are subject to many hours of direct sunlight as
this may overheat and damage the camera beyond repair. The maximum temperature inside the housing
should never exceed 50°C (122F).
290A Installation Instructions
Treat all visible seals with silicone at least once a year to prevent them
INSTAL GUIDE HOUSING ENV WHITE r3.1
Copyright © Axis Communications AB, 2007 Part No. 28432
January 2007