Digilock Curve Keypad Basic Install Manual - Page 8
Browse online or download pdf Install Manual for Rfid Systems Digilock Curve Keypad Basic. Digilock Curve Keypad Basic 13 pages. Deadlatch/deadbolt motorized rear
LOCK INSTALLATION STEPS
For illustration, a keypad front unit with a bolt rear unit is shown�
ATTENTION:
The rear-unit connector must be oriented with the
ribbon cable (as highlighted in fig-1). Improper connection may result in the lock to improperly function.
2
With the cable connector properly oriented. Insert the rear units
cable connector to the corresponding front units pin-connector
(as highlighted in fig-1).
4
Front View
Insert the front units nut-post through the doors mounting holes.
Hold and align the rear-unit using the same mounting holes
Note:
To avoid pinching of the ribbon cable a recessed pocket is
provided behind the rear unit.
6
Rear View
Test the lock while the door is open to ensure that the bolt or latch is operating properly. Refer to the testing instructions below.
Once installation is complete, refer to the DigiLink Site Setup Guide to add locks.
8
I NSTALL GU ID E
Keypad & RFID | Basic & Advanced
red wire
3
fig-1
The LED will flash red 3 times accompanied with a three-tone
beep, then followed by the LED flashing green 3 times.
Note:
The audible/visual feedback may only indicate that the
metal pin's have made contact. It is necessary to further insure
that both connectors are properly seated and connected
(as highlighted in fig-2).
5
Use the screw chart
to select the proper
screw length for your
door thickness.
Insert the screw with lock-washer through the mounting holes.
Tighten screws to the torque level of:
Note:
Overtightening of the mounting hardware may result in
the lock to improperly function.
positioned on the top of the
21.4 kgf/cm² ±20%
fig-2
Rear View
Front View