• 0 - DEACTIVATION - the device does not respond to alarm data
Parameter No. 14 - Switch type connector, you may choose
frames
between momentary and toggle switches.
• 1 - ALARM ON - the device turns on after detecting an alarm
Default value: 1
• 2 - ALARM OFF - the device turns off after detecting an alarm
• 3 - ALARM FLASHING - the device periodically changes its status
Options for changing the parameter:
to the opposite when it detects an alarm (lights on/off alternately)
0 - momentary switch
1 - toggle switch
Fibaro Double Relay Switch has two independent alarm groups (i.e.
each of its channels may respond in an individual way to received
alarm data-frames).
Parameter No. 15 - Operation of the Dimmer and Roller Shutter
Controller - enabling this option allows the user to dim
lighting/shut roller by associating Dimmer/Roller Shutter
VII Operating Fibaro Switch
Controller and holding or double press of double switch (only
mono-stable switch).
Default value: 0
Fibaro Switch may be operated using the following control
elements:
Available configuration parameters:
0 - Dimmer/Roller Shutter Controller control is not active
− any controller compatible with the system (e.g. Home Center
1 - Dimmer/Roller Shutter Controller control is active
controller)
− a mobile phone (e.g. iPhone and phones from other manufacturers
with appropriate software)
Parameter No. 16 - Saving the state of the device after a power
− tablet (such as iPad)
failure. Fibaro Switch returns to the last position saved before
− PC, using a web browser
a power failure.
− push-buttons connected to inputs S1 and S2
Default value: 1
− service button B, located inside the housing (activates learn mode)
Options for changing the parameter 0-1
VIII Procedures for malfunctions
0 - Fibaro Switch does not save the state after a power failure, it
returns to "off" position
1 - Fibaro Switch saves its state before power failure
The device does not respond to a pre-programmed transmitter:
• Make sure that the maximum range is not exceeded and the signal
Possibility to change the configuration of the following
path is not obstructed by metal surfaces such as metal cabinets, etc.
parameters [30 – 33, 40 - 43].
• Make sure the device is not in the programming mode, or repeat
0 - DEACTIVATION - the device does not respond to alarm data
the programming process.
• Or repeat the programming process.
frames
1 - ALARM RELAY ON - the device turns on after detecting an alarm
2- ALARM RELAY OFF - the device turns off after detecting an alarm
3 - ALARM FLASHING - the device periodically changes its status to
IX Guarantee
the opposite, when it detects an alarm within 10 min.
1. The Guarantee is provided by FIBAR GROUP Sp. z o.o.
(hereinafter "Manufacturer"), based in Poznan, ul. Lotnicza 1; 60-421
Parameter No. 30 - General Alarm, set for relay no. 1.
Poznan, entered in the register of the National Court Register kept
by the District Court in Poznań, VIII Economic Department of the
Default value: 3[byte] ALARM FLASHING
National Court Register, no. 370151, NIP 7811858097, REGON:
301595664.
Parameter No. 40 - General Alarm, set for switch no. 2.
2. The Manufacturer is responsible for equipment malfunction
resulting from physical defects (manufacturing or material) of the
Default value: 3[byte] ALARM FLASHING
Device for 12 months from the date of its purchasing.
3. During the Guarantee period, the Manufacturer shall remove any
Parameter No. 31 - Alarm of flooding with water, set for relay
defects, free of charge, by repairing or replacing (at the sole
no. 1.
discretion of the Manufacturer) any defective components of the
Device with new or regenerated components, that are free of
Default value: 2[byte] ALARM RELAY OFF
defects. When the repair impossible, the Manufacturer reserves the
right to replace the device with a new or regenerated one, which shall
be free of any defects and its condition shall not be worse than the
Parameter No. 41 - Alarm of flooding with water, set for relay
original device owned by the Customer.
no. 2.
4. In special cases, when the device cannot be replaced with the
Default value: 2[byte] ALARM RELAY OFF
device of the same type (e.g. the device is no longer available in the
commercial offer), the Manufacturer may replace it with a different
device having technical parameters similar to the faulty one. Such
Parameter No. 32 - Smoke, CO, CO2 Alarm. Set for relay no. 1.
activity shall be considered as fulfilling the obligations of the
Manufacturer. The Manufacturer shall not refund money paid for the
Default value: 3[byte] ALARM FLASHING
device.
5. The holder of a valid guarantee shall submit a guarantee claim
Parameter No. 42 - Smoke, CO, CO2 Alarm. Set for relay no. 2.
through the guarantee service. Remember: before you submit a
guarantee claim, contact our technical support using telephone or
Default value: 3[byte] ALARM FLASHING
e-mail. More than 50% of operational problems is resolved remotely,
saving time and money spent to initiating guarantee procedure. If
remote support is insufficient, the Customer shall fill the guarantee
Parameter No. 33 - Temperature Alarm, set for relay no. 1.
claim form (using our website - www.fibargroup.com) in order to
obtain claim authorization.
Default value: 1[byte] ALARM RELAY ON
When the guarantee claim form is submitted correctly, the Customer
shall receive the claim confirmation with an unique number (Return
Merchandise Authorization -RMA).
Parameter No. 43 - Temperature Alarm, set for relay no. 2.
6. The claim may be also submitted by telephone. In this case, the
Default value: 1[byte] ALARM RELAY ON
call is recorded and the Customer shall be informed about it by a
consultant before submitting the claim. Immediately after submitting
the claim, the consultant shall provide the Customer with the claim
Parameter No. 39 - Active flashing alarm time.
number (RMA-number).
Default value: 600
7. When the guarantee claim form is submitted correctly, a
Available configuration parameters: [1-65535][ms]
representative of the Authorised Guarantee Service (hereinafter as
"AGS") shall contact the Customer.
VI Additional Functionality
8. Defects revealed within the guarantee period shall be removed
not later than 30 days from the date of delivering the Device to AGS.
Operating alarm data frames
The guarantee period shall be extended by the time in which the
Fibaro system allows user to set response of devices to alarm
Device was kept by AGS.
situations
(response
to
data-frames ALARM_REPORT
and
SENSOR_ALARM_REPORT) Fibaro Double Relay Switch responds
9. The faulty device shall be provided by the Customer with complete
to the following types of alarms:
standard equipment and documents proving its purchase.
• General Purpose Alarm - GENERAL PURPOSE ALARM [0x00]
10. Parts replaced under the guarantee are the property of the
• Smoke Alarm - ALARM CO2 [0x02], ALARM CO [0x01], ALARM
Manufacturer. The guarantee for all parts replaced in the guarantee
SMOKE [0x03]
process shall be equal to the guarantee period of the original device.
• Water Flooding Alarm - ALARM WATER [0x05]
The guarantee period of the replaced part shall not be extended.
• Temperature Alarm - ALARM HEAT [0x04]
11. Costs of delivering the faulty device shall be borne by the
Alarm data-frames are sent by devices that are system sensors (e.g.,
Customer. For unjustified service calls, the Service may charge the
flood sensors, smoke detectors, motion detectors, etc.).
Customer with travel expenses and handling costs related to the
case.
The device may respond in the following manner to received
data-frames (settings are configured in configuration parameters,
see section V Configuration ):
12. AGS shall not accept a complaint claim only when:
• the Device was misused or the manual was not observed,
• the Device was provided by the Customer incomplete, without
accessories or nameplate,
• it was determined that the fault was caused by other reasons than
a material or manufacturing defect of the Device
• the guarantee document is not valid or there is no proof of
purchase,
13. The Manufacturer shall not be liable for damages to property
caused by defective device. The Manufacturer shall not be liable for
indirect, incidental, special, consequential or punitive damages, or
for any damages, including, inter alia, loss of profits, savings, data,
loss of benefits, claims by third parties and any property damage or
personal injuries arising from or related to the use of the Device.
14. The guarantee shall not cover:
• mechanical damages (cracks, fractures, cuts, abrasions, physical
deformations caused by impact, falling or dropping the device or
other object, improper use or not observing the operating manual);
• damages resulting from external causes, e.g.: flood, storm, fire,
lightning, natural disasters, earthquakes, war, civil disturbance, force
majeure, unforeseen accidents, theft, water damage, liquid leakage,
battery spill, weather conditions, sunlight, sand, moisture, high or low
temperature, air pollution;
• damages caused by malfunctioning software, attack of a computer
virus, or by failure to update the software as recommended by the
Manufacturer;
• damages resulting from: surges in the power and/or telecommuni-
cation network, improper connection to the grid in a manner
inconsistent with the operating manual, or from connecting other
devices not recommended by the Manufacturer.
• damages caused by operating or storing the device in extremely
adverse conditions, i.e. high humidity, dust, too low (freezing) or too
high ambient temperature. Detailed permissible conditions for
operating the Device are defined in the operating manual;
• damages caused by using accessories not recommended by the
Manufacturer
• damages caused by faulty electrical installation of the Customer,
including the use of incorrect fuses;
• damages caused by Customer's failure to provide maintenance and
servicing activities defined in the operating manual;
• damages resulting from the use of spurious spare parts or
accessories improper for given model, repairing and introducing
alterations by unauthorized persons;
• defects caused by operating faulty Device or accessories.
15. The scope of the guarantee repairs shall not include periodic
maintenance and inspections, in particular cleaning, adjustments,
operational checks, correction of errors or parameter programming
and other activities that should be performed by the user (Buyer).
The guarantee shall not cover natural wear and tear of the Device
and its components listed in the operating manual and in technical
documentation as such elements have a defined operational life.
16. If a defect is not covered by the guarantee, the Manufacturer
reserves the right to remove such defect at its sole discretion,
repairing the damaged or destroyed parts or providing components
necessary for repair or replacement.
17. This guarantee shall not exclude, limit or suspend the Customer
rights when the provided product is inconsistent with the purchase
agreement.
This Device may be used with all devices
certified with Z-Wave certificate and should be
i
compatible with such devices produced by
other manufacturers.
Any device compatible with Z-Wave may be added
to Fibaro system.
FIBARGROUP
FIBARO
In case of any technical questions contact customer service centre
in your country.
www.fibargroup.com