Fibar Group FGS-222 Operating Manual
Browse online or download pdf Operating Manual for Switch Fibar Group FGS-222. Fibar Group FGS-222 2 pages. Double relay switch
ENG
Technical Information
• Controlled by FIBARO system devices or any Z-Wave controller.
•
Electronic switch is a remote control unit.
• Microprocessor control.
• Active element: electromagnetic, micro-gap relay switch.
• The device may be operated by momentary and toggle
push-buttons.
•
To be installed in wall switch boxes of dimensions allowing for
installation, conforming to provisions of applicable regulations.
I General information about Fibaro system
FIBARO is a wireless system, based on Z-Wave technology.
FIBARO provides many advantages when compared to similar
systems. In general, radio systems create a direct connection
between the receiver and transmitter. But the radio signal is
OPERATING MANUAL
weakened by various obstacles located on its path (apartment
walls, furniture, etc.) and in extreme cases it fails to transfer
DOUBLE RELAY SWITCH
required data. The advantage of FIBARO system is that its devices
apart from being transmitters and receivers of signals, they are also
FGS-222-EN-A-v1.01
a signal "duplicators". When a direct connection path between the
transmitter and the receiver can not be established, the connection
may be achieved through other intermediate devices.
FIBARO is a bi-directional wireless system. It means that the signal
is not only sent to the receivers but also the receivers send the
Remotely Controlled Double Relay Switch of Fibaro System is
confirmation of its reception. This operation confirms their status so
designed to operate in a wall switch box or in locations where the
to check whether they are active. Safety of the FIBARO system
control of an electric device (up to 1.5kW) is needed.
transmission is comparable to the safety of transmission in data bus
wired systems.
It is also possible to send a signal to any system that is to be
integrated with Fibaro system.
FIBARO operates in the free band for data transmission. The
frequency depends on radio regulations in individual country . Each
Specifications
FIBARO network has its own unique network identification number
(home ID), which is why it is possible to co-operate two or more
independent systems in a single building without any interference.
Power supply:
110 - 240V ~
50 - 60Hz
Although Z-Wave is quite new technology, it has already become
recognizable and officially binding standard, similarly to Wi-Fi.
Power consumption:
to 0,8W
Many manufacturers in various industries offer solutions based on
Z-Wave technology, guaranteeing their compatibility. This means
Operational temperature:
0 - 35°C
that the system is open and it may be extended in the future. Find
more information at www.fibaro.com.
Dimensions (L x W x H):
42,50 x 38,25 x 20,30 mm
FIBARO generates a dynamic network structure. After FIBARO
For installation in boxes:
Ø ≥ 50mm
system is switched on, the location of its individual components is
automatically updated in real-time through status confirmation
Rated load current:
6,5A per channel for resistive
signals received from devices operating in a "mesh" network.
load, but total current can not
exceed 10A*
The In-Wall Double Relay Switch is hereinafter referred to as Fibaro
Switch. It is designed to switch on/off devices connected to its
Overcurrent protection:
required external 10A circuit
terminals using radio waves, controllers and a push button directly
breaker
connected to Fibaro Switch.
Active element:
micro-gap relay switch μ
II Assembling Double Relay Switch
Device control:
remotely - radio waves
directly - push buttons
Radio protocol:
Z-Wave
Radio signal power:
1mW
Radio Frequency:
868,4 MHz EU;
908,4 MHz US;
921,4 MHz ANZ;
869,0 MHz RU;
865,2 MHz IN;
Range:
up to 50 m outdoors
up to 30 m indoors
(depending on building materials)
Comply with EU directives:
RoHS 2011/65/EU
LVD 2006/95/EC
EMC 2004/108/EC
R&TTE 1999/5/EC
1. Before installation ensure that the voltage supply is
disconnected.
2. Connect Double Relay Switch as shown on the diagram.
3. Place the switch in the switch box.
4. Arrange the antenna (tips are presented further).
Single switch - mains electricity power connection
L
N
Double switch - mains electricity power connection
L
N
Fig.1 Wiring diagrams for Double Relay Switch.
NOTES FOR THE DIAGRAM:
N - terminal for neutral lead
L - terminal for live lead
CAUTION
IN - input terminal for load power supply
Q1 - output terminal of the first load
Read this manual before attempting to install
Q2 - output terminal of the second load
!
the device! Failure to observe recommendations
S2 - terminal for key no. 2
included in this manual may be dangerous or cause
S1 - terminal for key no. 1 (has the option of entering the device in
a violation of the law. The manufacturer, Fibar
learning mode)
Group Sp. z o.o., will not be held responsible for any
B - service button (used to add or remove a device from the system)
loss or damage resulting from not following the
instructions of operating manual.
!
CAUTION
Product must be installed on a 10A line.
DANGER
Danger of electrocution! Electronic switch is
designed to operate in electrical home installation.
Faulty connection or use may result in fire or electric
shock.
DANGER
Danger of electrocution! All works on the device
may be performed only by a qualified and licensed
electrician. Observe national regulations.
Fig.2 Installation of Fibaro Relay Switch in wall switch box.
DANGER
Danger of electrocution! Even when the device is
CAUTION
turned off, voltage may be present at its terminals.
!
The switch box must be compliant with the relevant
Any
works
introducing
changes
into
the
national safety standards and it's depth should not
configuration of connections or the load must be
be less than 60mm.
always performed with disconnected voltage
(disable the fuse).
CAUTION
The device is designed for installation in wall
!
switch boxes and can work only with the electrical
CAUTION
connectors compliant with the relevant safety
Do not connect the device to loads exceeding
!
standards.
recommended
values.
Connect
only
in
accordance with the diagram presented in the
manual. Improper connections may be dangerous.
NOTE
i
Durability of the device depends on applied load.
For resistive load (light bulbs, etc.) and 6,5A current
per channel, the durability exceeds 200 000
switches.
TIPS FOR ARRANGING THE ANTENNA:
i
Locate the antenna as far from metal elements as
possible (connecting wires, bracket rings, etc.) in
order to prevent interferences.
i
Metal surfaces in the direct vicinity of the antenna
(e.g. flush mounted metal boxes, metal door
frames) may impair signal reception!
i
Do not cut or shorten the antenna - its length is
perfectly matched to the band in which the system
operates.
i
NOTE
It should be noted that only the push-button
connected to S1 terminal and service push-button
S1 S2
L N
B enables "learning" mode (Include/ Exclude).
B
Q2 Q1 IN
SWITCH
DICTIONARY:
• Adding (Inclusion) - Z-Wave device learning mode, allowing to
add the device to existing Z-Wave network.
• Removing (Exclusion) - Z-Wave device learning mode, allowing
to remove the device from existing Z-Wave network.
• Association (linking devices) - direct control of other devices
within the Z-Wave system network.
• Multi-channel association - controlling other multi-channel
devices within the Z-Wave network.
III Activating Double Relay Switch
1. Installing the Double Relay Switch
STEP 1
S1 S2
L N
Connect the device in accordance with the wiring diagram
presented in Figure 1. Switch on the mains voltage.
B
Q2 Q1 IN
[Adding/Removing] Double Relay Switch [to/from] Z-wave
SWITCH
network
STEP 2
Double Relay Switch must be placed within the range of Home
Center controller, as adding mode requires direct communication
with the controller.
STEP 3
Find key no. 1 which allows to switch circuit 1 on, in accordance
with the diagram
STEP 4
Set the Home Center controller in add/remove mode (see the
controller's manual)
STEP 5
Add Double Relay Switch to the network by pushing three times key
no. 1 or push-button B located inside the housing of the device. For
toggle switch perform 3 position changes.
During the installation it is recommended to use a
momentary key connected to S1.
STEP 6
The controller indicates when the device is correctly added to the
network, (see the manual of Home Center controller).
CAUTION
Double Relay Switch cancels the "learning" mode
!
after key no. 1 is pressed once. Therefore, pressing
key no. 1 four times will not add the devices to the
network. The same applies to push-button B.
CAUTION
Double Relay Switch is set by default to operate
with momentary switches (i.e. single-pole switch or
!
bell switch). While adding Double Relay Switch to
the network with toggle switches, ensure that all
switch contacts are open (off), because closing
them results in activating the push-button and this
will prevent adding the device to the network.
2. Resetting Double Relay Switch
Fibaro Switch provides two methods for resetting.
Method I : Reset by removing Double Relay Switch from the
existing Z-Wave network. The device may be removed using the
controller that has the ability to include/exclude devices from/to
Z-Wave network (see the manual of controller).
Method II : Reset by holding B button for 3 sec. after connecting
mains voltage to the Switch
3. Controlling Double Relay Switch by momentary or
V Configuration
toggle switches.
The following settings are available in the Fibaro interface as
Momentary switch (after releasing the push-button a spring
simple options that may be chosen by selecting the appropria-
automatically pushes back and disconnects the button)
te
box.
- Turning on/off circuit 1 or 2 - briefly press the push-button
In order to configure Fibaro Switch (using the Home Center
corresponding to a chosen circuit (see diagram).
controller), go to device options by clicking the following icon:
Toggle switch (operates as a two-position switch, it has no
Select „Advanced" tab.
spring that would push back the device after releasing manual
pressure)
Parameter No. 1 - Activate / deactivate functions ALL ON / ALL
- Turning on/off the circuit - change the position of selected
OFF.
push-button from the current position.
Default value: 255
Options for changing parameter 255, 0, 1, 2
4. Controlling Double Relay Switch using a
command: ALL ON / ALL OFF
Available configuration parameters:
255 - ALL ON active, ALL OFF active.
0 - ALL ON is not active ALL OFF is not active
Fibaro Switch responds to commands ALL ON / ALL OFF that may
1 - ALL ON is not active ALL OFF active
be sent by the controller. ALL ON / ALL OFF commands are usually
2 - ALL ON active ALL OFF is not active
implemented in Z-Wave remote control.
Parameter No. 3 - Auto off relay after specified time, with the
By default, Fibaro Switch accepts both active commands ALL ON
possibility of manual override - immediate Off after button
and ALL OFF. Settings may be changed by entering an appropriate
push.
value into configuration register no. 1 (see configuration)
Default value: 0
Available settings:
5. Controlling Double Relay Switch using Home
0 - manual override disabled. After single button push the relay turns
Center controller
on and automatically turns off after specified time.
1 - manual override enabled. After single button push the relay turns
After adding Double Fibaro Switch to the network, it will be
on and automatically turns off after specified time. Another button
represented in Home Center by the following two icons (one icon
push turns the relay off immediately.
represents one channel):
Parameter No. 4 - Auto off for relay 1.
Default value: 0
Available settings:
[1 - 65535] (0,1 s – 6553,5 s) Time period for auto off, in miliseconds
0 - Auto off disabled
Parameter No. 5 - Auto off for relay 2.
Default value: 0
Fig.3 Icons of Double Relay Switch shown by
Available settings::
Home Center controller
[1 - 65535] (0,1 s – 6553,5 s) Time period for auto off, in miliseconds
0 - Auto off disabled
Turning on/off the device connected to Double Relay Switch is
performed by pressing ON/OFF icon.
Parameter No. 6 - Sending commands to control devices
assigned to 1-st association group (key no. 1).
IV Association
Default value: 0
Available configuration parameters:
Association enables Fibaro Switch to directly control a device
included in Z-Wave network e.g. Dimmer, Switch (ON-OFF), Roller
0 - commands are sent when device is turned on and off
Shutter or scene (scene may be controlled only through the Home
Center controller).
1 - commands are sent when device is turned off. Enabling device
does not send control commands. Double-clicking key sends 'turn
on' command, dimmers memorize the last saved state (e.g. 50%
i
brightness).
Association ensures direct transfer of control
commands between devices, and is performed
2 - commands are sent when device is turned off. Enabling device
without participation of the main controller.
does not send control commands. Double-clicking key sends 'turn
on' command and dimmers are set to 100% brightness.
Fibaro Switch provides association of three groups.
NOTE: Parameter 15 value must be set to 1 to work properly.
This activates the double-click functionality - dimmer/roller
1st group is assigned to key no. 1
shutter control.
2nd group is assigned to key no. 2
Parameter No. 7 – Sending commands to control
assigned to 2-nd association group (key no. 2).
3rd group reports state of devices. Only one device can be
associated to this group.
Default value: 0
Fibaro Switch enables user to control up to 5 normal devices, and
Available configuration parameters:
5 MultiChannel devices in group no. 1 and no. 2, group no. 3 has
only one field. One field is reserved for the network controller.
0 - commands are sent when device is turned on and off
1 - commands are sent when device is turned off. Enabling device
To add an association (using the Home Center controller), go to
does not send control commands. Double-clicking key sends 'turn
on' command, dimmers memorize the last saved state (e.g. 50%)
device options by clicking the following icon:
2 - commands are sent when device is turned off. Enabling device
Select the "device options" tab. Then specify to which group and
does not send control commands. Double-clicking key sends 'turn
what devices are to be associated. Sending relevant information to
on' command and dimmers are set to 100% brightness.
devices added to associated groups may take even a few minutes.
Info: Parameter 15 must be set to 1 to make this parameter work
properly. This activates the double-click functionality - dimmer/roller
shutter control.
WARNING
!
When Fibaro Switch sends control commands and
a new command is issued, then the current one
Parameter No. 13 - Assigns bistable key status to the device
command transmission is interrupted to send new
status.
commands.
Default value: 0
FGS-222 Fibaro Switch supports the operation of multi-channel
Available configuration parameters:
devices. Multichannel devices are devices that include two or more
0 - [On / Off] device changes status on key status change.
circuits inside one physical unit.
1 - Device status depends on key status: ON when the key is ON,
OFF when the key is OFF.
FGS-222 Double Relay Switch is a multichannel device. It means
that it has two independent executive circuits - each circuit is
recognized by the Home Center controller as a separate device.
i
Accordingly, each channel is represented by an independent icon.
The first channel is operated by a push-button connected to S1
terminal and it is the main (default) channel.
The association of the second channel of the double relay
switch may be operated only by devices supporting
multi-channel association !
devices
Remote control from Fibaro System is still
possible. This function is useful when you want
display status of external devices, e.g. Motion
Sensor, in Fibaro System.