FIBARO FGMS-001 Operating Manual - Page 9
Browse online or download pdf Operating Manual for Security Sensors FIBARO FGMS-001. FIBARO FGMS-001 11 pages. Motion sensor
Also for FIBARO FGMS-001: Operating Manual (20 pages), Operating Manual (2 pages)
16
This parameter provides backward compatibility with controllers not
supporting Z-Wave+.
Available settings: 0 - backward compatible tamper alarm sent to
Default setting:
40. Illuminance report - threshold
This parameter determines the change in light intensity level result-
ing in illuminance report being sent to the main controller.
Available settings: 0 - reports are not sent
Default setting:
42. Illuminance report - interval
i
NOTE
Time interval between consecutive illuminance reports. The reports
Frequent illuminance
are sent even if there is no change in the light intensity.
reports will shorten
the battery life. Pa-
Available settings: 0 - periodical reports are not sent
rameter value under
5 may result in block-
ing the temperature
Default setting:
reports.
60. Temperature report - threshold
This parameter determines the change in measured temperature that
will result in new temperature report being sent to the main controller.
Available settings: 0 - reports are not sent
Default setting:
62. Temperature measuring - interval
i
NOTE
Time interval between consecutive temperature measurements. The
Temperature
meas-
shorter the time, the more frequently the temperature will be meas-
urements
are
still
ured, but the battery life will shorten.
performed during the
wake up, even if the
Available settings: 0 - temperature is not measured
periodic measuring is
disabled
(parameter
62 set to 0).
Default setting:
i
NOTE
64. Temperature report - interval
Frequent temperature
Time interval between consecutive temperature reports. The reports
reports will shorten
are sent even if there is no change in the temperature.
the battery life. Pa-
Available settings: 0 - periodical reports are not sent
rameter value under
5 may result in block-
ing the illuminance
Default setting:
reports.
ADvAnCED PARAMETERS
5th association group
1 - backward compatible tamper alarm sent in
broadcast mode
0
Parameter size:
1 [byte]
1-32767 (illuminance in lux)
200 (200 lux) Parameter size:
2 [bytes]
1-32767 (in seconds)
3600 (1h)
Parameter size:
2 [bytes]
1-255 (0.1-25.5°C, 0.1°C step)
20 (1°C)
Parameter size:
2 [bytes]
1-32767 (in seconds)
900 (900s)
Parameter size:
2 [bytes]
1-32767 (in seconds)
0
Parameter size:
2 [bytes]
66. Temperature offset
The value to be added to the actual temperature, measured by the
sensor (temperature compensation).
Available settings: -1000-1000 (-1000-1000°C, 1°C step)
0 (0°C)
Default setting:
Parameter size:
80. Visual LED indicator - signalling mode
This parameter determines the way in which visual indicator behaves
after motion has been detected.
Available settings: 0 - LED inactive,
values from 1 to 9 - single long blink at the mo-
ment of reporting motion. no other motion will
be indicated until alarm is cancelled.
1
-
colour
is
temperature
2 - Flashlight Mode, 3 - white, 4 - red, 5 - green,
6 - blue, 7 - yellow, 8 - cyan, 9 - magenta
values from 10 to 18 - single long blink at the
moment of reporting motion and one short
blink each time the motion is detected again.
10 - colour is temperature dependent,
11 - Flashlight Mode, 12 - white, 13 - red,
14 - green, 15 - blue, 16 - yellow, 17 - cyan,
18 - magenta
values from 19 to 26 - single long blink at the
moment of reporting motion and two short
blinks each time the motion is detected again.
19 - colour is temperature dependent,
20 - white, 21 - red, 22 - green, 23 - blue,
24 - yellow, 25 - cyan, 26 - magenta
10
Default setting:
Parameter size:
81. Visual LED indicator - brightness
This parameter determines the brightness of the visual LED indicator
when indicating motion.
Available settings: 0 - brightness determined by the illuminance
(parameters 82 and 83)
1-100 (1-100%)
50 (50%)
Default setting:
Parameter size:
82. Visual LED indicator - illuminance for low indicator brightness
Light intensity level below which brightness of visual indicator is set
to 1%.
Available settings: 0 to value of parameter 83 (in lux)
Default setting:
100
Parameter size:
17
2 [bytes]
i
NOTE
Flashlight
Mode
-
visual indicator glows
in white for 10 sec-
onds. If value of pa-
rameter 80 is set to 11,
each detected motion
extends the glowing
by next 10 seconds.
dependent,
1 [byte]
1 [byte]
!
CAUTION
The value of parame-
ter 83 must be higher
than the value of pa-
rameter 82.
2 [bytes]
ADvAnCED PARAMETERS