Also for Siemens SIMATIC NET: Operating Instructions Manual (29 pages), Operating Instructions Manual (50 pages), Operating Instructions Manual (28 pages), Assembly Instructions Manual (6 pages), Product Information (6 pages), Installation Manual (40 pages), Installation Manual (50 pages), Installation Manual (40 pages), Reference Manual (14 pages), Installation Manual (48 pages), Operating Instructions Manual (32 pages)

Siemens SIMATIC NET Installation Manual
Installing the Device
2.6.2 Connecting DC Power
1.
2.
3.
4.
12
Connect the positive wire from the power source to the positive/live (+/L)
terminal on the terminal block.
1
2
3
Positive/Live (+/L) Terminal
1
Negative/Neutral (-/N) Terminal
2
Surge Ground Terminal
3
Braided Ground Cable
4
Figure 2.6
Terminal Block Wiring
Connect the negative wire from the power source to the negative/neutral (-/N)
terminal on the terminal block.
Using a braided wire or other appropriate grounding wire, connect the surge
ground terminal to the chassis ground connection. The surge ground terminal
is used as the ground conductor for all surge and transient suppression circuitry
internal to the unit.
Connect the ground terminal on the power source to the chassis ground
terminal on the device. For more information, refer to
(Page
9)".
"Grounding the Device
RUGGEDCOM RP100
Installation Manual, 01/2021, C79000-G8976-1011-05