When the machine has detected the blade is broken, the following screen will
appear:
Simply acknowledge with the OK button and change the blade. Please follow the
procedure for changing a broken blade as detailed later in the manual (section F-B).
Air Blast (option):
This is an air blast output after each cut. This can typically be used to blow away cut
pieces from a conveyor.
This option can be enable or disable. The parameters to set are:
Delay after cut:
It is the delay between the cut completion and the start of
the air blast in milliseconds.
Duration:
Duration of the air blast in milliseconds.
Scrap Transition Delay: The air blast is automatically disable when the machine
is cutting scrap. It is possible to set a delay to reactivate
the air blast after the transition of cutting bad to
good product. This avoids bad parts to blow away and get
mixed with the good ones. The delay is set in milliseconds.