Also for Siemens SINAMICS G120: Getting Started (46 pages), Operating Instructions Manual (32 pages), Getting Started (30 pages), Hardware Installation Instructions (2 pages), Installation Instructions And Owner's Manual (2 pages), Installation Instructions (2 pages), Installation Instructions (2 pages), Compact Operating Instructions (32 pages), Manual (42 pages), Getting Started (50 pages), Device Manual (34 pages), Quick Install Manual (2 pages), Application Description (50 pages), Compact Operating Instructions (2 pages), Applications Manual (34 pages), Compact Operating Instructions (2 pages), Compact Operating Instructions (2 pages)

Siemens SINAMICS G120 Manual
3 Function Principle of the Application Example
For more information on the "SINA_SPEED" block refer to the Online Help of the
Note
TIA Portal or to the "DriveLib" documentation.
https://support.industry.siemens.com/cs/ww/en/view/109475044
Instance data block
The "SINA_SPEED" block interface is restricted to few inputs and outputs. All
signals of standard telegram 1 are available via the instance data block at all times.
The instance data block "InstSinaSpeed" contains the following information:
Function block inputs (1)
Function block outputs (2)
Standard telegram 1 structure in the statistical tag range (3)
Figure 3-4: "InstSinaSpeed" instance data blocks
1
2
3
Drehzahlachse mit SINA_SPEED
Entry-ID: 109485727,
V1.0,
06/2017
12