Siemens FX-C Repair Instructions - Page 14
Browse online or download pdf Repair Instructions for Washer Siemens FX-C. Siemens FX-C 34 pages.
4.10
Motor / motor actuation
Function:
The motor is controlled (open-loop and closed-loop) by phase control.
The actual speed value of the tachogenerator signal is compared with
the required value of the electronics module. The direction of rotation
is changed by two deenergised reversing relays. An integrated
protector in the motor winding disconnects the motor in the event of
an overload. The control does not disconnect the motor with
a tachogenerator fault but continues trying to restart the motor.
A motor fault is displayed only at the end of the programme. In these
appliances is not necessary an aditional relais for reaching 1400 min-
1. The following speeds apply to the washing machine with empty
drum:
►
Wool:
►
Wet:
►
Rinse:
►
Wash:
►
Spin :
Teoric speed
1400
1300
1200
1100
1000/900
800/700
600
500
►
Measurement speed (unbalanced load):100 min
209_58300000115677_ara_en_f.doc – 26.03.08
-1
27 min
-1
35 min
-1
56 min
-1
56 min
(see table)
Max. Speed
1360
1300
1140
1100
960
750
600
500
-1
If an unbalanced load is detected, the speed is reduced in the final
spin cycle as follows:
Appliance
-1
min
1400
1200
1000
800
600
Before each spin speed acceleration, the imbalance is scanned for
20 seconds at 100min-1 (A). The imbalance is scanned up to 15x (up
to 2x for wool).
If there is a large imbalance, the spin cycle is terminated at approx.
100 min-1.
+/- 5 %
+/- 3 %
+/- 3 %
+/- 3 %
+/- 2,5 %
+/- 1 %
Start-up attemps
1-5
6-8
9-15
max
-1
-1
n
min
1100 min
900 min
max
-1
-1
n
min
1000 min
800 min
max
-1
-1
n
min
1000 min
800 min
max
-1
-1
n
min
800 min
800 min
max
-1
-1
n
min
600 min
600 min
> 15
-1
-1
0 min
-1
-1
0 min
-1
-1
0 min
-1
-1
0 min
-1
-1
0 min