Sony BVP-E30 series Manual - Page 25

Browse online or download pdf Manual for Camcorder Sony BVP-E30 series. Sony BVP-E30 series 34 pages. Sdtv portable cameras
Also for Sony BVP-E30 series: Operation Manual (36 pages), Brochure & Specs (14 pages), Operation Manual (38 pages)

Sony BVP-E30 series Manual

3-4-3. LAN IF Setting Menu

Set the equipment when connected to LAN. Implement the following settings in accordance with the connection Target.
< E T H E R
I / F
C O N F >
A U T O
N E G O T I A T I O N
A U T O
M D I X
C O N N E C T
C O N F I G U R A T I O N
C O N N E C T
S P E E D
D U P L E X
M O D E
M D I / M D I X
S E L E C T
L I N K
C O N D I T I O N

3-4-4. 700PTP Setting Menu

< 7 0 0 P T P
S E T T I N G >
N S
M O D E
:
L E G A C Y
M C S
M O D E
: ( C L I E N T )
C C U
N O
: (
M A S T E R
I P
A D D R E S S
1 9 2 .
1 6 8 .

3-4-5. NETWORK Reset Menu

< N E T W O R K
R E S E T >
A L L
R E S E T
Camera Network System
N 0 1
T O P
:
O N
:
O N
:
1 0 0 M
:
F U L L
:
M D I
:
( U P )
S E T
N 0 2
T O P
1 )
0 .
1 0 0
N 0 3
T O
Item
Function
AUTO
Set AUTO NEGOTIATION (ON/OFF)
NEGOTIATION
AUTO MDIX
Polarity of cable is set automatically
(ON
*1
/OFF)
CONNECT SPEED
Set the connection speed (10M/100M)
DUPLEX MODE
Set the communication method
(FULL/HALF)
MDI/MDIX SELECT
Set polarity of cable (MDI/MDIX)
LINK CONDITION
Network communication condition is
displayed (UP/DOWN)
UP :
DOWN : Not connected
SET
The above setting is saved
*1 : Valid when AUTO NEGOTIATION is set to "ON".
*2 : Automatic setting when AUTO NEGOTIATION is set to "ON".
*3 : Automatic setting when AUTO MDIX is set to "ON".
Item
Function
NS MODE
Set the communication mode
(LEGACY/BRIDGE/MCS)
MCS MODE
Displays that CCU/HDCU is Client
(Display only)
CCU NO
Equipment number (camera number) is
displayed
*
(Blank/1 to 96)
MASTER
Set IP address of the Master equipment in the
IP ADDRESS
MSU mode (0 to 255)
* : Setting is performed by using the setting switch on the board.
For the setting method, refer to Section "3-4-6. Equipment Setting" of
this manual.
Item
Function
ALL RESET Return the network setting to the default value
when shipped from the factory
Factory default setting:
. IP ADDRESS :
. NS MODE :
. AUTO NEGOTIATION : ON
. AUTO MDIX :
. CONNECT SPEED :
. DUPLEX MODE :
. MDI/MDIX :
*2
*2
*3
Connected
0.0.0.0
LEGACY
ON
100M
FULL
MDI
3-9 (E)