User Set

Main set values can be saved to the channels 1 to 16 of
USERSET. Refer to "Command List" (page 38) for
items to be saved. The factory setting is saved to channel
0, which cannot be overwritten.
Setting example
:
1
Shutter 3 ms, Gain 3 dB, FVAL signal is output to
GPO3 connector (This setting is saved to the channel
1.)
>EXPOSURE 3000
>GAIN 3
>GPO 9 3
>USERSET-SAVE 1
Setting example
:
2
The user set saved in the channel 2 is loaded.
>USERSET-LOAD 2

User set name

Strings that are 31 characters long can be assigned to
channels 0 to 16. For example, you can assign names
such as "setting1" and "setting2" in accordance with the
settings.
Command
USERSET-NAME
31 characters of your choice

User set memory

This is one of the items to be saved in the user set
channel. Signed 32-bit numbers are assigned to slots 0 to
15.
Configuration diagram of user set
Parameter
Factory setting

Free Memory

Signed 32-bit numbers can be saved and loaded to 8192
areas.
Command
FREE-MEMORY

User ID

User IDs are unique names that can be assigned to
cameras. A string that is 15 characters long can be
assigned.
Command
USER-ID
15 characters of your choice

Saving and Startup

The startup setting can be determined by USERSET-
DEFAULT. This is also used to check which user set
settings are currently being used.
Usage example:
Startup with the setting saved in the user set channel 3.
>USERSET-DEFAULT 3
(Restart or RESET command)
Check which user set settings are the current settings.
>USERSET-DEFAULT
0
OK
35
Parameter1
Parameter2
31
0 to 8191
-2
to 2
Parameter
31
- 1