Camera Control Commands
Command Form
When inputting commands, separate a command and a parameter by a space, and press <Carriage Return> to confirm.
Commands are not case sensitive. Lower case can be used for input strings on USER-ID. Input format and an input
example are shown below.
Input format:
Command Param1 Param2 Param3 Param4 Param5 Param6 Param7 <CR>
Input example:
ROI 640 480 8 6 <CR>
Command Input and Response
Camera echoes back against characters (alphabetic, numeric), space, backspace and Enter; otherwise, other invalid
characters are ignored. When a command is successfully completed, the status will be echoed.
Input: Gain 6<CR>
Output: OK<CR>
Status
OK
ERROR: Invalid argument number.
ERROR: Invalid parameter.
ERROR: Not implemented.
ERROR: Access denied.
ERROR: Busy
SYNTAX ERROR!
Explanation (Example)
Successfully completed
The argument number of the parameter is invalid.
(Width 100 100)
The parameter is invalid.
(Width abc)
The command is not supported.
(Vbin of a color camera)
Commands are limited.
(A trigger mode related command is controlled by SP-TRG-MODE=1.)
The command cannot be received.
The command is not correct.
(Widtt 100)