Cisco UCS B200 M4 Installation And Service Note - Page 20
Browse online or download pdf Installation And Service Note for Server Cisco UCS B200 M4. Cisco UCS B200 M4 30 pages. For e5-2600 v4 series cpus
Also for Cisco UCS B200 M4: Installation And Service Note (46 pages), Upgrade Manual (9 pages), Servicing Manual (24 pages)
Procedure
Step 1
Open both DIMM connector latches.
Figure 15: Installing DIMMs in the Blade Server
Step 2
Press the DIMM into its slot evenly on both ends until it clicks into place.
DIMMs are keyed, if a gentle force is not sufficient, make sure the notch on the DIMM is correctly aligned.
Be sure that the notch in the DIMM aligns with the slot. If the notch is misaligned you may damage the DIMM,
Note
the slot, or both.
Step 3
Press the DIMM connector latches inward slightly to seat them fully.
Supported DIMMs
The DIMMs supported in this blade server are constantly being updated. A list of currently supported and available DIMMs is in the
specification sheets at:
http://www.cisco.com/en/US/products/ps10280/products_data_sheets_list.html
Cisco does not support third-party memory DIMMs, and in some cases their use may irreparably damage the server and require an
RMA and down time.
20