Ariston ABS VLS Flat 100 Technical Manual - Page 8
Browse online or download pdf Technical Manual for Water Heater Ariston ABS VLS Flat 100. Ariston ABS VLS Flat 100 18 pages. Storage electric water heaters
2.5 Power board, connections and probes
Sensor Test Table (ohmic resistance values as a function of temperature)
T [°C]
R [kΩ]
T [°C]
-40
195,7
-10
-35
148,2
-5
-30
113,3
0
-25
87,6
5
-20
68,2
10
-15
53,6
15
R [kΩ]
T [°C]
R [kΩ]
42,5
20
12,1
33,9
25
10,0
27,2
30
8,3
22,0
35
6,9
17,9
40
5,8
14,7
45
4,9
main power board (PCB)
power cable (PCB - HE1: red; PCB - HE2: blue)
HE1 probe with cable (width = 8 mm)
HE2 probe with connector (width = 6,5 mm)
HE2 probe cable
T [°C]
R [kΩ]
T [°C]
50
4,2
55
3,5
60
3,0
65
2,6
70
2,2
75
1,9
8
R [kΩ]
T [°C]
80
1,7
110
85
1,5
115
90
1,3
120
95
1,1
125
100
1,0
105
0,9
R [kΩ]
0,8
0,7
0,6
0,5